Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

B.

Airjets are plugged.

B.

Wet a soft, non-abrasive cloth with

white vinegar and wipe the

plugged hole. Rinse the area with

clean water to avoid long-term

exposure of the vinegar to the bath

or airjet surface.

C.

Check valve does not work.

C.

Replace the check valve. Refer to

your installer or wholesale dealer.

D.

Blower motor does not work.

D.

Replace the blower motor. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

8.

Blower motor operates,

air bubbles are formed,

zone controls work, but

variable speed feature

does not work.

A.

Blower motor inlet is blocked.

A.

Clean blower motor inlet.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

C.

User keypad does not work.

C.

Replace the user keypad. Refer to

your installer or wholesale dealer.

D.

Blower motor does not work.

D.

Replace the blower motor. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

9.

Blower motor won’t turn

off when the On/Off

button on user keypad is

pressed.

A.

User keypad does not work.

A.

Replace the user keypad. Refer to

your installer or wholesale dealer.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

C.

Control does not work.

C.

Replace the control. Refer to your

installer or wholesale dealer.

10.

A zone does not produce

air bubbles but another

zone operates normally.

A.

Zone is not selected.

A.

Select the zone according to the

instructions in

″User Keypad and

Bath with Airjets Modes/Features.

B.

Butterfly valve does not work.

B.

Replace the butterfly valve. Refer to

your installer or wholesale dealer.

C.

Loose, disconnected, or

damaged wiring harness.

C.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

D.

User keypad does not work.

D.

Replace the user keypad. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

11.

Surge mode does not

work.

A.

User keypad does not work.

A.

Replace the user keypad. Refer to

your installer or wholesale dealer.

B.

Control does not work.

B.

Replace the control. Refer to your

installer or wholesale dealer.