background image

Service the Filter

IMPORTANT!

If the flow from the faucet decreases from its original

volume, it is a possible indication that the in-line filters are partially
blocked. Follow these procedures to clean the filters.

Turn off the water supplies.

Disconnect the flex hoses from the filter assemblies.

Remove the filter assemblies from the supply stops.

Using two wrenches, separate the housing from the adapter.

Remove the screen and clean all debris from the screen and the
housing.

Return the screen to the housing, making sure the convex side of
the screen faces the supply stop.

Thread the housing and adapter together.

Reattach the filter assemblies to the supply stops and flex hoses.

Housing

Screen

Adapter

Flex
Hose