2. Unscrew the six screws on the bottom casing. Remove the bottom casing If necessary,

arrange the electrical wires to run through the 1” diameter hole on the top or the rear of

the hood. Refer to Figure 5.

3. Using references on Table 1 and measurements on page 21 center the hood in place

beneath the cabinet and flush with the front of the cabinet.


1” Diameter

Hole



Figure 4 Figure 5

4. Draw electrical wires through cabinet access opening.

5. Place screw (not provided) into the exact center of each knockout hole. Make sure all

screws are in place before tightening screws. CAUTION: MAKE SURE THE HOOD IS

SECURE BEFORE RELEASING.

Ductwork Installation

6. Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork

above. Use duct tape to make all joints secure and air tight.

7. Continued on page 16.