Typical installations – Kenmore 625.38445 User Manual

Page 6

Advertising
background image

6

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com

Typical Installations

NOTE: Be sure to allow a minimum space of 2” under the

filter for removing the sump (to change the cartridge).

WATER

IN

WATER
OUT

Nut

Figure 6

Optional

Shutoff

Valve

Brass

Ferrule

Compression

Adaptor

INLET

3/4” NPT

MATERIALS & TOOLS NEEDED

2 compression adaptors, 3/4” NPT x com-
pression end to fit existing copper pipe
Teflon tape
Tubing cutter
Sandpaper or emery cloth
2 wrenches, either open end or adjustable
jaw, sized to fit compression adaptors

A. INSTALLATION ON COPPER PLUMBING USING COMPRESSION FITTINGS

Figure 3

B. SOLDERED COPPER INSTALLATION

C. THREADED INSTALLATION

D. UNDERSINK INSTALLATION

(Filtering Water to One Faucet)

Figure 4

Figure 5

IN

OUT

IN

OUT

IN

OUT

Optional

Shutoff

Valve (2)

Optional

Shutoff

Valve (2)

WATER

IN

WATER
OUT

3/4” Copper

Pipe, as

required

Adaptor, 3/4” NPT

x Sweat (Apply

4 wraps of

Teflon Tape)

WATER

IN

WATER
OUT

3/4”

Nipple

(2)

3/4” Hex

Nipple

(2)

Union

Fitting

(2)

NOTE: To change the filter

cartridge, refer to
the instructions on
Pages 11 & 12 in
this manual.

COLD

Shutoff Valve

SINK

NOTE: Be sure to allow

a minimum
space of 2” under
the filter for
removing the
sump (to change
the cartridge).

See Note in Figure 3

See Note in Figure 3

Optional

Shutoff Valve

Apply 4 wraps of

Teflon Tape

Advertising