Installation - type b – Kenmore 625.38445 User Manual

Page 8

Advertising
background image

8

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com

Installation - Type B

B. WATER FILTER ON HOUSE MAIN WATER PIPE, TO FILTER ALL HOUSEHOLD WATER

USING SOLDERED COPPER FITTINGS (See Figure 4 on Page 6)

MATERIALS AND TOOLS NEEDED:

You will need 2 sweat adaptors, 3/4" NPT x sweat (sweat
end to fit your main water pipe), lead-free solder and
flux, soldering torch, Teflon tape, sandpaper or emery
cloth, open end (to fit sweat adaptor) or adjustable jaw
wrench.

INSTALLATION STEPS

CAUTION: Heat created when soldering can damage
the water filter’s plastic parts. Be sure to use the follow-
ing procedure to protect the water filter.

1. IMPORTANT: Turn off the water supply to the main

pipe. Open a high and low faucet in the water system
to drain the pipe.

2. On the main water pipe, where you will install the fil-

ter, use a tubing cutter to remove a section of pipe
about 12" long. Use sandpaper or emery cloth to thor-
oughly clean and remove all burrs and rough edges,
from both pipe ends.

NOTE: When soldering, use lead-free solder and flux

only. Be sure pipe and fittings are properly
cleaned.

3. Solder a sweat adaptor onto one of the pipe ends (See

Figure 11).

4. Place, but do not solder, a straight connector onto the

other pipe end (See Figure 11).

5. Remove the sump from the filter head and set the

sump aside.

6. After it cools, apply 4 wraps of Teflon tape to the

threads on the sweat adaptor fitting (See Figure 12).

7. With the IN side of the water filter toward incoming

water, carefully, turn the filter head onto the sweat
adaptor fitting (See Figure 12). Do not cross-thread, or
over-tighten and crack the filter head.

8. Turn a sweat adaptor fitting into the other side of the

filter head and hand tighten only. Using a tape meas-
ure or ruler, measure the distance “D” as shown in
Figure 13. Mark this same dimension on a length of
copper pipe. Cut the length of pipe.

9. Remove the sweat adaptor fitting from the filter head

and solder to the cut length of pipe.

10. After it cools, apply 4 wraps of Teflon tape to the

threads on the sweat adaptor fitting. Apply flux and

Figure 11

Straight

Connector

Sweat
Adaptor

IN

OUT

Figure 12

Filter
Head

WATER FLOW

Sweat

Adaptor

Apply

Teflon Tape

D

D

Figure 13

place the pipe end of the soldered assembly into the
straight connector. Then, turn the adaptor end into
the filter head and tighten.

11. Solder both sides of the straight connector.

12. Before replacing the sump and turning on the water

supply, install the filter cartridge (See Page 11).

NOTE: Read the “Grounding Information” on Page 7,

and comply with the instructions if required to
maintain continuity.

continued