Kohler K-10103 User Manual

Page 10

Advertising
background image

Complete the Installation (cont.)

Place the handle in the vertical position, as shown.

Rotate the handle clockwise, then reposition the handle at the 2
o’clock position.

For hot and cold water supply installations:

Rotate the handle as

needed to achieve the desired water temperature.

For tempered or filtered water installations:

Turn the handle

counterclockwise to the full cold position.

Secure the cover and handle to the valve with two screws
(provided).

7. Troubleshooting

Symptoms

Probable
Causes

Recommended Action

1.

No water

flow.

A.

There is a

loose

connection.

A.

Remove the valve cover and

check the connections from the

battery to the solenoid and

from the battery holder to the

sensor. Make sure that the

connector arrows are aligned

and that the connection is

secure.

B.

The

supply

stops are

in the

″OFF″

position.

B.

Confirm the supply stops are in

the

″ON″ position.

C.

The

wires/cables

are

pinched or

damaged.

C.

Remove the cover and inspect

the wires/cables for cuts or

damage. If the wires are cut or

damaged, order a new

solenoid, sensor assembly,

sensor extension cable, or

battery holder. Do not pinch or

damage the wires during

reassembly.

1056542-2-B

10

Kohler Co.

Advertising
This manual is related to the following products: