KENYON

Model #

Stove Description

Voltage AC

Rated Wattage
(W) & Amps (A)

Suggested Wire Size Based On Wire
Run Length - d (feet) One Way

B61044

213 A/E w/ Black
Glass Lid

120 Volts - 60 Hz

1100 W / 10 A

d < 35 feet : 14 AWG

35 < d < 80 feet: 12 AWG

B61045

213 A/E w/ Black
Glass Lid

240 Volts - 50/60 Hz

1100 W / 5 A

d < 125 feet: 14 AWG

B61046

213 A/E w/ White
Glass Lid

120 Volts - 60 Hz

1100 W / 10 A

d < 35 feet : 14 AWG

35 < d < 80 feet: 12 AWG

B61047

213 A/E w/ White
Glass Lid

240 Volts - 50/60 Hz

1100 W / 5 A

d < 125 feet: 14 AWG


B61048

436 A/E w/ Black
Glass Lid

120 Volts – 60 Hz

2200 W / 20 A

d < 20 feet: 14 AWG

20 < d < 45 feet: 12 AWG
45 < d < 70 feet: 10 AWG

B61049

436 A/E w/ Black
Glass Lid

240 Volts - 50/60 Hz

2200 W / 10 A

d < 90 feet: 14 AWG


INSTALLATION INSTRUCTIONS

NOTE: Installation should comply with ABYC standard A-3, “Recommended Practices and Standards
Covering Galley Stoves,” and/or the “Fire Protection Standards for Motorcraft” NFPA #302.



MOUNTING THE ALCOHOL COOKTOP

LOCATING THE COOK TOP AWAY FROM FLAMMABLE MATERIALS

Before you cut your countertop:
Make certain the Cook Top will be far enough from flammable
materials!

! CAUTION

Do not cut the opening in your countertop until you ensure that there will be adequate horizontal
and vertical clearances from the Cook Top to the nearest flammable materials- fabric, plastic,
wood- (except the countertop itself).

Minimum Distances are:

40cm (16”) Horizontally 1M (39”) Vertically



It is the installer’s and/or purchaser’s responsibility to ensure that the Cook Top is installed in a
location such that a fire hazard is not created.

IN EUROPE:
Contact the authorities appointed by the government in each separate country

IN USA:
Contact ABYC, 3069 Solomons Island Road, Edgewater Maryland 21037-1416
tel (410) 956 1050 fax (410) 956 2737 internet [email protected]