Commissioning/setting – Kohler CFI230J User Manual

Page 14

Advertising
background image

14

CFI230J

15

CFI230J

COMMISSIONING/SETTING

1. General

1.1.

Turn on the water supply to the Digital Mixer.

1.2.

Check for leaks over the complete system.

1.3.

Turn on the electrical supply to the Digital Mixer.

For the Pumped Version with the Slide Rail System, pump priming can be helped by removing the handset

and lowering the end of the hose into the shower tray.

2. Set the Maximum Temperature

Note!

The maximum temperature of the unit can only be set when the unit has not been used for a period of

10 minutes or after switching the unit’s electrical supply OFF and ON.

2.1.

Temperature Selection - Set the temperature control knob to the desired position, as per the table

below.

2.2.

Enabling - Press and momentarily hold the Warm Up/Stop and High push-buttons at the same time.

Release the push-buttons and press them again within 2 seconds. The High push-button will flash and beep

three times to confirm the selection is successful.

3. Lock Mode

Note!

Allows you to lock the unit during operation.

3.1.

There are two Safety Lock Modes

Option

1

- Locks the mixer to your flow and temperature settings.

Option 2

- Locks the interface so no push-buttons can be used.

Note!

The Warm Up/Stop push-button will be illuminated on the interface used to set the lock mode, no

other interface will be illuminated.

Temperature Control

Temperature Selection °C

Knob

Position

1

Factory Set 45°C

2

45°C

3

36°C

4

38°C

5

40°C

6

42°C

7

45°C

8

47°C

9

48°C

Setting Option 1

Operate the shower and set the desired flow and temperature, then press and momentarily hold the

Warm Up/Stop

and Medium push-buttons at the same time. The Medium push-button will flash and

beep three times to confirm the selection is successful.

The mixer is locked to your selected temperature and flow. Pressing any flow push-button turns the

mixer ON. Pressing the Warm Up/Stop push-button turns the mixer OFF.

Caution!

If the temperature control knob is altered while the mixer is in standby mode or while

the shower is in operation, the water temperature settings will be changed to the new setting next time

the shower is used.

Note!

Selecting the Warm Up/Stop and Medium push-buttons at the same time again, cancels the

lock mode option set. The Medium push-button will flash and beep three times

Setting Otion 2

Note!

This can only be set when the mixer has not been used for a period of 10 minutes. Switching the

unit’s electrical supply OFF and ON cancels the lock mode.

Press and momentarily hold the Warm Up/Stop and Medium push-buttons at the same time. The

Medium

push-button will flash and beep three times to confirm the selection is successful. The

interfaces are locked.

Note!

Selecting the Warm Up/Stop and Medium push-buttons at the same time again, cancels the

lock mode option set. The Medium push-button will flash and beep three times

4. Timeout

Note!

Timeout allows you to run the shower for a set period of time before it automatically shuts off. This can

only be set when the unit has not been used for a period of 30 minutes or after switching the unit‘s electrical

supply OFF and ON.

4.1.

Timeout Selection - Set the temperature control knob to the desired position, as per the table below.

4.2.

Enabling - Press and momentarily hold the Warm Up/Stop and Low push-buttons at the same

time.

The

Low

push-button will flash and beep three times to confirm the selection is successful.

Temperature Control

Timeout (Minutes)

Knob

Position

1

30

2

30

3

3

4

4

5

5

6

6

7

7

8

8

9

9

Advertising