E. FIELD WIRING CONTROL BOX

COMPARTMENT - 230 V, 50 HZ

WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on page 2.

CAUTION: Risk of electrical shock. All services
must have an Earth Leakage Circuit Breaker
(ELCB) which will provide additional protection
against line-to-ground shock hazard. A separate
service is required for the whirlpool.

The whirlpool controls and system have been prewired
at the factory. A licensed electrician should make a
routine service connection to the field wiring
compartment of the control box containing blue and
brown wires and earth lug.

* For bonding in accordance with National and Local
Codes.

Field Wiring
Compartment

Bonding
(Earthing) Lug*

Air
Actuator

Air
Actuator
Tube

Pump

Control
Box

F. CONNECT CONTROL BOX - 230 V, 50 HZ

Connect service to the field wiring compartment of the
control box. The 50 Hz model control box contains blue
and brown wires and earth lug.

A 230 V, 15 A, 50 Hz dedicated circuit is required.
Provide an Earth Leakage Circuit Breaker.

Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes. A 230 V, 15A, 50 Hz separate
circuit is required.

Earth
(Ground) Lug

Earth
(Ground)

Neutral

Earthing Lug (for
bonding in accor-
dance with national
and local codes)

Blue
(Neutral)

Brown
(Phase)

Wire Connectors

Phase (Line)