Roughing in k-1210-ac, k-1211-ac, Ordering information, Required electrical service – Kohler Builder Portfoilio Whirlpool baths K-1215-AC User Manual

Page 7: Product information, Installation notes, Rough-in

Advertising
background image

1.25>132

É

FIELD WIRING COMPARTMENT

PUMP

18”

1-7/8”

8-7/8”

PUMP/CONTROL ACCESS

36”

1-3/4”

21”

1-1/8”

2-7/8”

3”

1-1/2” I.P.S. THR’D

1-1/2” O.D.

3-1/4”

59-9/16”

7

106548-

CA

(9437)

Kohler Co., Kohler WI

3. ROUGHING-IN: K-1210-AC, K-1211-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch
transmitter.

Information contained in this roughing-in also applies to
K-1211-J1-AA, K-1211-J1-AB and K-1211-JA-AA.

Whirlpool with wall timer

K-1210-AC

Whirlpool with air actuator (shown)

K-1211-AC

Accessories/hardware:

Drain

K-7161-AF recom-

mended

Vinyl tiling-in bead*

K-1179

optional

*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

C. PRODUCT INFORMATION

Fixture:

basin area

top area

weight

Bathing well

39” x 22”

54” x 27”

85 lbs.

water depth

capacity

To overflow

15-1/2”

65 gals.

Pump:

hp

V

Hz

A

60 Hz

1/2

120

60

8

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before
beginning installation.

*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler-
ances in ANSI Standard Z124.1.

No change in measurements if connected with drain
illustrated.

Cut-out

34-1/2” x 58-1/2”

Minimum access:

Pump/control box 20” W x 15” H panel required