Kobe Range Hoods CH9130SQB User Manual

Page 13

Advertising
background image

11


OPERATION INSTRUCTIONS

This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30-

second delay shutoff, two powerful centrifugal turbine impellers with baffle filters, and two bright 12-volt

20-watt halogen lights.

The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control

(On/Off). Refer to Figure 19.

Figure 19

TURN ON:

Press Power Control (On/Off) button once.
(Note: If any control button is not pressed within 10 seconds, power will be automatically

turned off).

The KOBE hood will start on Low speed. Each press of the Speed Control button will

cycle through the various speeds.

Press Speed Control A button to cycle from Low, Medium, High, or QuietMode.

Press Speed Control B button to cycle from Low, QuietMode, High or Medium.
(Note: Speed Control A or B will operate both fans. These two speed buttons vary the

speed quicker.)

Press Light Control button to turn halogen light on.



TURN OFF:

Press Power Control (On/Off) button once, panel lights will flash and power will be

completely shut off after 30 seconds.

OR

Press Power Control (On/Off) button twice, all power will be shut off immediately.

If only the lights are on, pressing Power Control (On/Off) button once will turn power

off after 30 seconds.

Speed Control A

Power Control

Speed Control B

Light Control

Advertising