LAMP Control

a) Dual LAMP Operation

All Models are equipped with a DUAL LAMP MODULE (Extra Bright).

The POWER REGULATION PCB on all Models contains a LAMP current circuit that can detect if the active
LAMP is on, indicated by a LED on the BACK PANEL.

If a LAMP fails, the MICROCONTROLLER receives the LAMP_CURR signal from the POWER REGULATION
PCB. It activates the MIRROR MOTOR and moves the MIRROR to the second LAMP position. Then the relay
K1 is energized and second LAMP is energized. The MICROCONTROLLER also energizes the LED for the
second LAMP. The LED’s are located on the BACK PANEL.

The Models 4020 - 9020 and 9020/CINE have a memory. This memory is storing the the current used lamp as
long as the lamp is defective. That means the mirror of the DUAL LAMP MODULE do not change his position
after a new lamp is inserted. This function can be disabled (see page 2-3).

The characteristic of the lamp curve is no longer generated by a PLL circuit on the MASTERBOARD. Up to
now it is stored in the Software LAMP Control memory and the TRIAC will be triggered from the
MICROCONTROLLER.

Zero-Cross

Circuit

M

Mirror

Motor

Dissolve

Logic

Relay

Mirror

Motor

Driver

Micro

Controller

Master Board

Dual Lamp

Modul

Power Regulation Board

91VAC

Lamp Current

Detection and

Switch off

Relay

Driver

L1

L2

Zero_Cross

DATA

SYNC

Lamp_curr

Lamp

Current

Relay

Driver

Economy

82VAC

Software

Lamp

Control

SOFTWARE TRIGGER

GND

figure 3-9

SM 2547-1

Service Manual

Kodak AG, Stuttgart

3-11

03/98