NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Mobile Home Installations

In addition to the standard installation instructions, the following instruc-

tions may be required by local, state or federal building codes.

• Installation should be in accordance with the Manufactured Home and

Safety Standard (HUD), CFR 3280, Part 24.

• The stove must be permanently bolted to the floor using 1/4" diameter

lag screws. The screws can be inserted through the holes in the

pedestal located behind the side doors. The lag screws must be an

adequate length to extend through the hearth pad and into the floor.

A minimum of two lag screws must be used.

• Connecting the Winslow™ PS40 stove to outside combustion air is

required in manufactured home installations and when required by

local building codes. An outside air inlet must be provided for com-

bustion and be unrestricted while unit is in use. Use a galvanized or

stainless steel pipe for the duct (the outside air inlet on the stove is 3”

diameter). The air intake on the exterior of the home should always be

located a minimum of 18” below the flue termination. The Inlet shall

remain free of obstruction while unit is in operation and constructed

in a manner so as to prevent material from dropping into the inlet or

into the area beneath the dwelling. The inlet shall also have a screen

with openings not larger than 1/4" to prevent rodents from entering.

• The stove must be permanently electrically grounded to the steel

chassis of the manufactured home using a 8 GA copper wire and a

serrated or star washer (to penetrate paint or protective coating to

ensure grounding). The location selected for ground attachment to the

stove must be dedicated for this purpose. Grounding must comply

with NFPA-70-latest edition standards, CSA C22.1-latest edition in

Canada, as well as any local codes.

Vertical

If the length of pipe exceeds 15 feet, 4 inch pipe rather than 3 inch vent

pipe should be used.

WARNING: DO NOT INSTALL THIS STOVE IN A SLEEPING ROOM

IN A MANUFACTURED HOME.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFAC-

TURED HOME FLOOR, WALL AND CEILING/ROOF MUST BE

MAINTAINED.

Outside Air Installations

Connecting the Winslow PS40 stove to outside combustion air is required

in manufactured home installations and when required by local building

codes. The stove’s air intake will accept 3” ID pipe to accommodate outside

air installations. The air intake on the exterior of the home should always

be located a minimum of 18” below the flue termination and must remain

free of obstruction. The inlet must also have a screen with openings not

larger than 1/4” to prevent rodents from entering.

Thermostat installation

The Winslow PS40 stove can be operated manually or by thermostat. The

stove comes from the factory wired to operate manually - see control

board operation on Page 19. A low voltage thermostat can be installed

on the stove. To install the thermostat:

1) Unplug the stove from the electrical outlet. Open the right side door

and lift out the control board from its retaining brackets. Locate the

light green wiring block at the bottom back of the board (see Figure

21), loosen the two screws B at the back of the block and remove the

U shaped jumper wire A protruding from the block.

2) Insert a wire from the thermostat into one of the slots from which

the jumper wire was removed. Repeat this process for the other

thermostat wire.

Retain the jumper wire for future reinstallation. See Page 19 for thermostat

operation instructions.

IMPORTANT NOTE: Install the thermostat per the manufacturers

instructions, provided with the thermostat. Failure to follow

manufacturers instructions could result in a malfunction. Pay

special attention to the thermostat location requirements. If the

location requirements are not adhered to the appliance, erratic

operation or failure may occur.

Do not mount the thermostat where it may be affected by:

• Radiant heat from the stove, fireplaces, sun or other heat

sources.

• Drafts or dead spots behind doors or in corners.

• Hot or cold air from ducts.

Listed Pellet Pipe

Ceiling Firestop

Storm Collar

Roof Flashing

Rain Cap

Outside Air Pipe

Figure 20

Figure 21

Wiring Block

B

A

Rear View of Control Board

A = Jumper Wire

B = Screws

A

B

Rear View of Control Board

Wiring Block