HEARTH PROTECTION

VENT TERMINATION REQUIREMENTS

This appliance requires noncombustible floor protection (the hearth pad

or alternate floor protection material does not require a thermal rating).

A noncombustible floor protector must fully cover the area beneath the

appliance as illustrated in Figure 9.

If the floor protection is to be stone, tile, brick, etc., it must be mortared

or grouted to form a continuous noncombustible surface. In Canada, if a

chimney connector / venting extends horizontally over the floor, protection

must also cover the floor under the connector / venting and at least 2”

(51 mm) to either side (recommended but not required in the US).

Minimum Size Hearth Protection

1. Do not terminate the vent in any enclosed or semi-enclosed areas

such as a carport, garage, attic, crawlspace, narrow walkway, closely

fenced area, under a sundeck or porch, or any location that can build

up a concentration of fumes such as stairwells, covered breezeway,

etc.

2. Vent surfaces can become hot enough to cause burns if touched.

Non-combustible shielding or guards may be required.

3. Termination must exhaust above the inlet elevation. It is recommended

that at least five feet of vertical pipe be installed outside when the

stove is vented directly through a wall. This will create a natural draft

to prevent the possibility of smoke or odor during appliance shut

down or power failure and avoid exposing people or shrubs to high

temperatures.

4. The vent should terminate no less than four feet below, no less than

four feet horizontally from and no less than one foot above doors and

windows, or gravity/ventilation air inlets into the building.

5. The distance from the bottom of termination to grade is 12” (305 mm)

minimum unless otherwise specified by the vent manufacturer. The

distance between the bottom of the termination and a public walkway

should be a minimum of seven feet.

6. Locate the vent termination at least two feet away from combustible

materials such as shrubs, plants, grass, fences, roof overhangs and

adjacent buildings.

Stove Base

Firebox Front Edge

Hearth Protection

Outline of Stove Base

3-7/8”

(98mm)

6”

(152mm)

6”

(152mm)

6”

(152mm)

3-7/8”

(98mm)

9-5/8”

(245mm)

14-1/4”

(362mm)

9-5/8”

(245mm)

10-3/4”

(273mm)

8-7/8”

(225mm)

8-7/8”

(213mm)

7-9/16”

(192mm)

18-3/8”

(467mm)

7-9/16”

(192mm)

33-1/2”

(851mm)

28”

(711mm)

Figure 9

Figure 10

Alcove Installations

Minimum alcove height is 41” (1041 mm), minimum width is 42-1/4” (1073

mm) and maximum depth is 48” (1219 mm). Note, it is quite difficult to

load pellets into the hopper when installed in an alcove only 41” (1041

mm) high. For alcove wall clearances see parallel clearances below.

48”

(1219mm)

Figure 8

41”

(1041mm)

42-1/4”

(1073mm)