Warning, Important – Lennox Hearth 1000 User Manual

Page 10

Advertising
background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

14.0 CHECKING THE BURNER

There are no imitation fuel bed components, such as logs or

rocks, to install. The appliance features a ribbon burner which is

designed to produce a continuous band of flame over its length.

The burner should be visually inspected to ensure it is free from

any foreign matter. If it is necessary to clean or dust off the

burner then the glass door should be removed by removal of

the four retaining screws. Re-fit the glass door after cleaning or

inspection, ensuring a good seal.

15.0 CONNECTING A GAS LINE

A qualified gas appliance installer must connect the gas room

heater to the gas supply. Consult all local codes.

The installer must provide an ANSI approved manual shut off

valve, flex connector and 3/8" NPT fitting.

Route gas line using techniques and materials prescribed by

local and/or national codes. Only use pipe of 1/2" or greater size

to allow full gas volume to the gas fireplace. Undue pressure

loss will occur if the pipe is too small.

An external regulator must be used on all propane (L.P.G.)

heaters, in addition to the regulator fitted to the heater, to reduce

the supply tank pressure to 13" w.c. (maximum).

Regulator

Manual

Shut-Off

Valve

Union

Sediment

Trap

Fireplace or

Firebox Wall

Wall

Shut-Off

Key

Fireplace or

Firebox Wall

Down

3"

Figure 6

WARNING

Connecting directly to a unregulated propane (L.P.G.)

tank may cause an explosion.

An ANSI approved manual shut-off valve and union must be

installed upstream of the heater within the fireplace cavity

when rigid pipe is used. Ensure that a sediment trap is installed

upstream of the heater (Figure 4) within the structure’s piping

system to prevent moisture and contaminants from passing

through the pipe to the heater controls and burner. Failure to do

so could prevent the heater from operating reliably.

The heater gas inlet connection is 3/8” NPT at the regulator,

located below the burner, in the right hand side of the heater.

When tightening up the joint to the regulator hold the regulator

securely with a wrench to prevent the regulator from moving.

IMPORTANT

Hold heater regulator with a wrench to prevent move-

ment when connecting to inlet piping.

Advertising