NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

After having selected the final mounting position of the appliance, taking

into account the site requirements as specified in

these instructions,

the integrity of the wall, and the feasibility of the proposed supply pipe

routing, the firebox of appliance may be secured to the wall.

1.0 MOUNTING THE APPLIANCE

WARNING

The wall where the appliance is to be installed must

be capable of long-term support of the total load of

the appliance. Measures should also be taken to

ensure sufficient strength to withstand the force of

earthquakes, vibration and other external forces.

A full size fitting template is supplied to assist with wall mounting. (see

Figure 3).

If the heater is to be installed on a studded wall with conventional 16”

stud spacing then a wall mounting plate is supplied to enable this. NOTE:

THIS APPLIANCE MUST BE SECURED DIRECTLY TO THE STUDS AT THE

FIXING POINTS THAT ARE 16" DISTANCE (see template below). First

locate the studs and using suitable fixings, screw the mounting plate to

the wall via the four mounting holes. The heater may then be hung onto

the mounting plate. The bottom of the heater may be secured onto the

lower mounting studs using the wing-nuts or the hex nuts provided.

Mark the positions shown as “Fixing Points” on the wall. If the appliance

is to be mounted on the inner leaf of a conventional cavity wall, or a solid

wall, drill four holes using a 5/16" masonry bit, to a depth of 1-11/16".

Insert the fiber wall plugs provided.

If the appliance is to be mounted on a dry lined wall or a timber framed

construction wall then special cavity screw fixings will be required

which are not supplied with this product. These should be constructed

from metal and not plastic.

If a concealed gas connection is to be made ensure the gas supply pipe

is in it’s final position and can enter the appliance in the correct position

when the appliance is hung on the wall.

Figure 3 - Wall Fixing Template

To ensure customer safety, be sure to design the installation so that the

strength of both the wall and any wall fixings used are sufficient. Lennox

Hearth Products assumes no responsibility for injuries and damages

that may occur due to improper installation or handling.

The appliance should not be installed until all dry wall sanding and wall

painting has been completed.

Incorrect installation can cause the appliance to fall from the wall and

cause injury. Do not block the ventilation holes of the appliance. The

wall onto which the appliance is installed must be flat. Install only on a

vertical surface. Avoid sloped surfaces. Installation onto anything other

than a vertical wall may result in fire, damage or injury.

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.

Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4”
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20” of the heater sides. No combustible shelves of any
size are permitted above the heater.

Clearance to
combustible
sidewalls 4”
(both sides)

Clearance to combustible ceiling
32” measured from top of appliance
glass panel

Clearance in
front of
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4” entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y

similares por encima del calentador a cualquier distancia, ni a

una distancia de 20” de los laterales del calentador. No se

permiten estantes combustibles de cualquier tamaño por

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

F860487 - ISSUE A - PRW

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

CENTRE LINE

LINEA DE CENTRO

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

APPLIANCE OUTLINE

C

ONT

ORNO DE LA AP

ARA

TO

FocalPointFires Single 27/06/08

F860487

Lennox 1000 fitting template

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER

COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE

ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE
PARA MARCAR LOS PUNTOS DE FIJA-

CION.

RETIRE LA PLANTILLA ANTES DE COLO-

CAR LE APARATO.

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG

ONLY.

DO NOT RECESS OR INSET ANY PART OF

THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING

OF FIXING POINTS ONLY.

DO NOT INSTALL THE APPLIANCE WITH

THIS TEMPLATE IN PLACE.

PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4

FIXING POINTS

PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

16” (406mm)

8

13

/

16

” (225mm)

6

3

/

8

” (160mm)

3

1

/

8

(78

.6

mm)

CONCEALED

GAS INLET

ENTRADA DE

GAS OCULTA

Artwork Size: W1002 x H642