Lenovo THINKSERVER 3797 User Manual

Page 215

Advertising
background image

1

RAID controller

2

Retention bracket

3

SAS riser card

5. Remove the retention bracket from the current location:

a. Pinch the bottoms of both bracket posts and push the posts up out of the

SAS riser-card assembly.

b. Rotate the bracket

2 to free the bracket tab from the slot on the SAS

riser-card assembly

1 .

6. Install the retention bracket in the new location on the SAS riser-card assembly:

a. Insert the bracket tab

2 into the slot on the SAS riser-card assembly 1 .

b. Rotate the bracket so that the bracket posts align with the holes in the SAS

riser-card assembly.

c. Press the posts through the holes in the SAS riser-card assembly until they

click into place.

d. Install the SAS controller on the SAS riser card (see “Installing a SAS

controller on the SAS riser card” on page 204).

e. Install the riser-card assembly in the server (see “Installing the SAS riser

card and controller assembly” on page 202).

f. Connect the power cords and all external cables, and turn on the server and

peripheral devices.

Removing a SAS controller battery from the remote battery tray

To remove a SAS controller battery from the remote battery tray, complete the
following steps:

Chapter 6. Removing and installing FRUs

207

Advertising
This manual is related to the following products: