Troubleshooting

Description

Result

Configuring the MC-12 for V4 EQ

2-19

Version 4 EQ User Guide

The MC-12 calibrated the distance or output
level of the selected loudspeaker without error.

The selected loudspeaker is not present in the
loudspeaker setup according to the CUSTOM
or THX SETUP menu.

The calibrated distance is accurate, but the
microphones detected out-of-phase calibration
noise signals.

The microphones detected calibration noise
signals at unusually low levels.

The microphones did not detect calibration
noise signals, so the MC-12 could not calibrate
the distance of the selected loudspeaker.

At least one of the microphones did not detect
calibration noise signals at reasonable levels. As
a result, the distance calibrated for the selected
loudspeaker may not be accurate.

The microphones detected calibration noise
signals at unusually high levels.

The microphones detected calibration noise
signals at unusually low levels.

N/A

• Use the CUSTOM or THX SETUP menu to add the selected loudspeaker to the loudspeaker

setup. (The MC-12 does not calibrate for loudspeakers that are not present in the loudspeaker
setup.)

• Examine connections between the loudspeaker and the associated amplifier to ensure that

loudspeaker wires are not crossed. If the wiring is correct, the error message can be ignored.
(Some loudspeaker models will report a phase error even if no phase error exists.)

• Dipolar loudspeakers may produce this error. However, the MC-12 does not report the error

unless at least half of the microphones detect out-of-phase calibration noise signals.

• The microphones may be positioned too far from the selected loudspeaker or in a location

where echoes obscure calibration noise signals. Refer to

Repositioning the Microphones for

Automatic Calibration

(page 2-10) to ensure that the microphones are properly positioned

for automatic calibration.

• Examine microphone input connections to ensure that the microphones are properly connected

to the MC-12. Make sure microphone cable plugs are fully inserted for solid connections.

• Refer to

Repositioning the Microphones for Automatic Calibration

(page 2-10) to

ensure that the microphones are properly positioned for automatic calibration.

• Examine microphone input connections to ensure that the microphones are properly connected

to the MC-12. Make sure microphone cable plugs are fully inserted for solid connections.

• Refer to

Repositioning the Microphones for Automatic Calibration

(page 2-10) to

ensure that the microphones are properly positioned for automatic calibration.

• Decrease associated amplifier volume levels, including built-in subwoofer amplifiers.
• The microphones may be positioned too close to the selected loudspeaker. Refer to

Repositioning the Microphones for Automatic Calibration

(page 2-10) to ensure that

the microphones are properly positioned for automatic calibration.

• Increase associated amplifier volume levels, including built-in subwoofer amplifiers.
• The microphones may be positioned too far from the selected loudspeaker or in a location where

echoes obscure calibration noise signals. Refer to

Repositioning the Microphones for

Automatic Calibration

(page 2-10) to ensure that the microphones are properly positioned

for automatic calibration.

DISTANCES and OUTPUT LEVELS Results

(SPEAKER)

OK

(SPEAKER)

IS NOT ENABLED

(SPEAKER)

OUT OF PHASE

(SPEAKER)

SIGNAL TOO LOW

(SPEAKER)

UNABLE TO CALCULATE

(SPEAKER)

MAY NOT BE ACCURATE

(SPEAKER)

SPKR OUTPUT TOO HIGH

(SPEAKER)

SPKR OUTPUT TOO LOW