SP-125 PLUS

E-3

TROUBLESHOOTING

Observe Safety Guidelines
detailed in the beginning of this manual.

TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (28 vdc maximum) – weld
output.

Wire feed speed motor runs very
fast. Weld output, gas flow and fan
operate normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. If the wire drive motor is running

check to see if the correct wire
is in the machine.

2. If the wire drive motor is running

make sure that the correct drive
rolls are installed in the
machine.

3. Check for clogged cable liner or

feeding problems.

1. Make sure that the wire speed

control is not set at maximum.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

FEEDING PROBLEMS

PROBLEMS
(SYMPTOMS)

Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check gas supply, flow regulator

and gas hoses.

2. Check gun connection to

machine for obstruction or leaky
seals.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

GAS FLOW PROBLEMS

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact your
LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION