71 degrees (f) – Lux Products TX9600TS User Manual

Page 25

Advertising
background image

from 0°F to 9°F degrees (0°C to 5°C degrees). When set to 0 degrees, the
second heating stage is completely disabled while in regular Heat mode
(Emergency Heat mode will still function for heat pump configurations). The
Offset value will determine the number of degrees from the set point that will
be required for the second heating stage to turn on. This setting can be
used to conserve energy in situations where the second heating stage is
more costly to operate when compared to the first stage.

25

70˚F Set

Temperature

71

DEGREES (F)

** = Only applies if a second

heat stage is present

70

69

68

67

66

65

Swing

Setting=

#2 (+/- 0.5˚F)

Cut-In / Cut-Out

(1

st

Stage)

(2

nd

Stage) **

Cut-In / Cut-Out

Offset **
Setting=
4˚F degrees

Advertising