Installation, Instructions, Warning – Lincoln Electric WELDMARK 225 IM927 User Manual

Page 12: Caution

Advertising
background image

A-5

INSTALLATION

A-5

e. Place the Engine switch in the “Auto Idle” position.

f. Adjust the wire feed speed at the LN-15 and adjust

the welding voltage with the output “CONTROL” at
the welder. Output “CONTROL” must be set above 3.

Note: LN-15 Control Cable model will not work with

the WELDMARK 225.

CONNECTION OF THE LN-25
TO THE WELDMARK 225

Shut the welder off.

Connect the electrode cable from the LN-25 to
the“ELECTRODE” terminal of the welder.
Connect the work cable to the “TO WORK” termi-
nal of the welder.

Position the welder “Polarity” switch to the desired
polarity, either DC (-) or DC (+).

Position the “RANGE” switch to the “WIRE FEED”
position.

Attach the single lead from the LN-25 control box
to the work using the spring clip on the end of the
lead - it carries no welding current.

Place the engine switch in the “AUTO” position.

Adjust wire feed speed at the LN-25 and adjust
the welding voltage with the output “CONTROL”
at the welder.

NOTE: The welding electrode is energized at all
times, unless an LN-25 with built-in contactor is used.
If the output “CONTROL” is set below “3”, the LN-25
contactor may not pull in.

CONNECTION OF K930-2 TIG MODULE TO THE
WELDMARK 225.

The TIG Module is an accessory that provides high
frequency and shielding gas control for AC and DC
GTAW (TIG) welding. See IM528 supplied with the
TIG Module for installation instructions.

Note: The TIG Module does not require the use of a
high frequency bypass capacitor. However, if the
WELDMARK 225 is used with any other high frequen-
cy equipment, the bypass capacitor must be installed,
order kit T12246.

INSTRUCTIONS

ADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the roof and case
sides in place as this provides maximum protection
from moving parts and assures proper cooling air flow.

Read and understand all Safety Precautions before
operating this machine. Always follow these and any
other safety procedures included in this manual and in
the Engine Owner’s Manual.

WELDMARK 225

LOCATION / VENTILATION

The welder should be located to provide an unrestrict-
ed flow of clean, cool air to the cooling air inlets and to
avoid heated air coming out of the welder recirculating
back to the cooling air inlet. Also, locate the welder so
that engine exhaust fumes are properly vented to an
outside area.

STACKING

WELDMARK 225 machines cannot be stacked.

CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS

Shut off welder before making any electrical
connections.
------------------------------------------------------------------------

WIRE FEED (CONSTANT VOLTAGE)
CONNECTION OF LN-15 ACROSS-THE-ARC WIRE

FEEDER
The LN-15 has an internal contactor and the electrode
is not energized until the gun trigger is closed. When
the gun trigger is closed the wire will begin to feed
and the welding process is started.

a. Shut the welder off.

b. Set the Polarity switch to the desired polarity,

either DC (-) or DC (+).

c. Attach the single lead from the front of the LN-15

to work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire
feeder motor; it does not carry welding current.

d. Set the “RANGE” switch to the “WIRE FEED-CV”

position.

WARNING

DO NOT MOUNT OVER COMBUSTIBLE SUR-
FACES.
Where there is a combustible surface directly
under stationary or fixed electrical equipment, the
surface shall be covered with a steel plate at least
.06”(1.6mm) thick, which shall extend not more
than 5.90”(150mm) beyond the equipment on all
sides.
------------------------------------------------------------------------

CAUTION