Installation, Figure 1, Warning – Lincoln Electric WELDMARK 225 IM927 User Manual

Page 16: Connection of weldmark 225 to premises wiring

Advertising
background image

240 Volt
60 Hz.
3-Wire
Service

POWER

COMPANY

METER

240 VOLT

120 VOLT

120 VOLT

LOAD

N

NEUTRAL
BUS

GROUND

PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION

GND

N

NOTE: No. 6 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.

240 VOLT

GROUNDED CONDUCTOR

40 AMP
240 VOLT

DOUBLE
POLE
CIRCUIT
BREAKER

DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.

50 AMP, 120/240
VOLT PLUG
NEMA TYPE 14-50

50 AMP, 120/240 VOLT
RECEPTACLE

240 Volt

60 Hz.

3-Wire

Service

POWER

COMPANY

METER

240 VOLT

120 VOLT

120 VOLT

LOAD

N

NEUTRAL
BUS

GROUND

PREMISES

DISCONNECT AND

SERVICE

OVERCURRENT

PROTECTION

GND

N

NOTE: No. 6 COPPER CONDUCTOR CABLE SEE

NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE

SIZE RECOMMENDATIONS.

240 VOLT

GROUNDED CONDUCTOR

40 AMP

240 VOLT

DOUBLE

POLE

CIRCUIT

BREAKER

DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES

SERVICE OVERCURRENT

PROTECTION.

50 AMP, 120/240

VOLT PLUG

NEMA TYPE 14-50

50 AMP, 120/240 VOLT

RECEPTACLE

A-9

INSTALLATION

A-9

Connection of WELDMARK 225 to premises wiring
must be done by a licensed electrician and must
comply with the National Electrical Code and all
other applicable electrical codes.

Figure 1

CONNECTION OF WELDMARK 225 TO PREMISES WIRING

WARNING

WELDMARK 225

WELDMARK 225