background image

A-2

INSTALLATION

SAFETY PRECAUTIONS

Read entire installation section before starting

installation.

IDENTIFY AND LOCATE
COMPONENTS

If you have not already done so, unpack the
Handymig 170i from its carton and remove all packing
material around the Handymig 170i. Remove the fol-
lowing loose items from the carton (see Figure A.1):

1. Handymig 170i

2. Gun and cable assembly

(1)

3. Literature and miscellaneous includes:

a) This operating manual

b) A separate .030" (0.8 mm) contact tip

c) Hex key wrench for removal of drive roll.

4. 10 ft (3,0 m) work cable.

5. Work clamp.

6. Adjustable mixed-Gas Regulator & Hose.

(1)

The gun is ready to feed .023"

.025" (0.6 mm)

diameter wire.

ELECTRIC SHOCK can kill.

Only qualified personnel should perform

this installation.

Only personnel that have read and under-

stood the Handymig 170i Operating
Manual should install and operate this
equipment.

Machine must be plugged into a receptacle

which is grounded per any national, local
or other applicable electrical codes.

The Handymig 170i power switch is to be

in the OFF (

O

) position when installing

work cable and gun and when connecting
power cord to input power.

WARNING

FIGURE A.1

1

2

3

4

5

Handymig 170i

WELD

ING AMP

RANGE

WELD

ING AM

P RAN

GE

2

5-125

25

-125

6

A-2

Handymig 170i