E-3

E-3

TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Observe Safety Guidelines
detailed in the beginning of this manual.

PROBLEMS
(SYMPTOMS)

No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (33 vcd maximum)

weld

output.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. If the wire drive motor is running

make sure that the correct drive
rolls are installed in the machine.

2. Check for clogged cable liner or

contact tip.

3. Check for proper size cable liner

and contact tip.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Liquid Arc
Authorized Field Service Facility.

FEEDING PROBLEMS

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
LOCAL AUTHORIZED

LIQUID ARC

FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

PROBLEMS
(SYMPTOMS)

Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check gas supply, flow regulator

and gas hoses.

2. Check gun connection to

machine for obstruction or leaky
seals.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Liquid Arc
Authorized Field Service Facility.

GAS FLOW PROBLEMS