Troubleshooting – Lincoln International K2259-1 User Manual

Page 19

Advertising
background image

Cobramatic

®

Owner’s Manual - page 9

Section E

Troubleshooting

Troubleshooting

Symptom

Cause

Remedy

No wire feed at gun, feeder not oper-
ating, i.e., no slave motor or brake
solenoid.

F1 & F2 fuse(s) in feeder failed.

Check AC circuit. Replace fuse(s).

F3 (4 amp) fuse in feeder failed.

Check motor leads for shorts then
replace fuse.

Micro-switch defective/not being acti-
vated. Broken electrical cable.

Replace switch. Check switch for
operation. Check micro switch wires
for continuity.

Loose J2, J3, P.C. board connector.

Check J2, J3 connectors.

Brake solenoid inoperative.

Solenoid defective.

Replace solenoid.

Loose connector at J6.

Check J6 connector.

No wire feed at gun, feeder operating
properly.

Bad potentiometer.

Check potentiometer with meter.

Bad gun motor.

Check/Replace motor.

Broken electrical cable.

Check motor and potentiometer wires
for continuity.

Bad speed control/PCB.

Check/Replace P.C. board.

Wire feeds, but welding wire is not
energized.

Loose or no cable power supply con-
nections.

Check all power connections.

Contactor control cable loose or in
wrong position.

Check power supply owner’s manual
for location and type of contactor signal
required, i.e. closing contacts or AC.

Welding power source not working
correctly.

Check power supply for proper
operation.

Wire feeds erratically.

Dirty or worn conduit.

Blow out or replace conduit.

Incorrect pressure on drive rolls.

Adjust pressure at gun (Gold or Prince)

Idler roll stuck in gun.

Check for lock washer under idler roll,
or replace if damaged or worn.

Wrong size contact tip.

See contact tip table.

Wire feeds one speed only.

Bad potentiometer.

Check with meter.

Broken electrical cable in lead assy.

Check potentiometer wires for continu-
ity or shorts.

Bad speed control.

Check/Replace P.C. boards.

Wire walks out of drive rolls.

Idler roll upside-down.

Place groove in idler roll toward the
top.

Rear wire guide missing.

Replace wire guide.

Trigger inoperable or not operating
correctly.

Trigger mode configuration.

Check front panel Trigger Normal/
Latched toggle switch.

Purge not operating correctly.

Jumper incorrectly configured. Gas
solenoid malfunctioning.

Check jumper location per Jumper
Table in Appendix. Check cable con-
nections to gas solenoid Check valve
in gun.

No PosaStart Wire Speed Transition

Welding power cable and/or gun power
cable connected to wrong bolt on
power block.

Welding power cable to bottom bolt.
Gun power cable to top bolt.

Welding current not being sensed.

Check current sensor in power block.

Remote Functions Not Working

Wires not connected at TB1

Reseat all wire connections at TB1.

Advertising