Volt meter, Input / output configuration for tb1 – Lincoln International K2259-1 User Manual

Page 37

Advertising
background image

Cobramatic

®

Owner’s Manual - page 27

Monitor Wire Feed Speed
Use digital volt meter between: TB1 – 1(GND) and TB1 – 2(MSPD).
Measured value defined as: Reading x 100 = Wire Feed Speed.

Example: 3.54 VDC is equivalent to 354 IPM

GND

MSPD

TB1

1

2

3

4

5

6

7

8

VOLT METER

Remote/External Trigger
Install jumper between: TB1 – 1(GND) and TB1 – 3(TRIG) to trigger system.

GND

TRIG

TB1

1

2

3

4

5

6

7

8

SW

Arc Establish Relay Closure
External Contact Signal; Connect 24VDC relay coil between TB1 – 8 (24V)
and TB1 – 4 (ARC). When arc is established, the relay coil will close.

24V

ARC

ARC ESTABLISHED

ARC ESTABLISHED

TB1

1

2

3

4

5

6

7

8

K?

ARC ESTABLISHED RELAY

Input / Output Configuration for TB1