INSTALLATION

LFA 3.1 & 4.1 FUME EXTRACTION ARMS

A-3

INSTALLING THE LFA 3.1 OR 4.1
ARM ON A WALL MOUNTING
BRACKET

Only qualified personnel should install, use or service
this equipment.

------------------------------------------------------------------------

Leave the tape and plastic packaging on the extrac-
tion arm sections until the arm is completely installed
(including mounting the hood). The arm is spring-bal-
anced to compensate for the weight of the hood and
will spring out quickly if it is not mounted securely,
with the hood in place.

------------------------------------------------------------------------

MOUNTING THE WALL-MOUNTING BRACKET

Figure 1 shows suggested mounting methods for
installation on various wall types.

Figure 2 shows drilling dimensions.

Standard mounting height is approximately 7 ft. from
the floor to the lower mounting holes.

WARNING

9" (230 mm)

8.3"

(210 mm)

7.0 ft.

Fig. 2

CAUTION

3/8"

3/8"

3/8"

3/8"

Fig. 1

Mounting on a thin wall (recom-
mended minimum wall thickness
5 in. (100 mm), using four 3/8 in.
(M10) threaded rods.

Mounting on a thick wall using
four 3/8 in. (M10) cotter bolts.

Mounting on a steel I-beam using four
3/8 in. (M10) threaded rods and two
box-profile stabilizers (1x1x0.1 in.,
30x30x3 mm)