ROUTINE MAINTENANCE

Every 3 months, check the integrity of the outside of
the extraction arm and clean it with a non-agressive
detergent.

Every 12 months:

Check the flexible hoses and rubber seals for cracks

or damage; replace if necessary.

Check the inside of the extraction arm and clean it

thoroughly.

Check and lubricate the hinge points with lubricating

oil. (See Fig. 10 C)

Check and lubricate the steel cable near the balance

wheel with lubricating grease. (See Fig. 10 B)

Check the steel cables for wear.

Check and adjust the friction setting of the hood,

middle, and base hinges. (See Fig. 10 A, Fig. 11)

Check the balance construction of the extraction

arm. (See Fig. 10 A)

Check the operation of the airflow throttle valve.

C

F

B

360

°

B

C

A

A

C

C

C(2x)

A

A

C(2x)

A

C

B

C-1

MAINTENANCE

C-1

LFA 3.1 & 4.1 FUME EXTRACTION ARMS

Fig. 10

B

B

Fig. 11

Adjust friction
with a wrench

Lubricate
with grease

Lubricate
with oil

Advertising
This manual is related to the following products:

4.1