Part 3 electrical connections, Warning, Connect range cord – LG LDE3017SW User Manual

Page 6: Electrical connection requirements

Advertising
background image

6

Part 3

ELECTRICAL CONNECTIONS

Protection cover

The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below the
rear of the drawer body and use the conduit hole (1

1

/

8

”)

instead of power cord hole (1

3

/

8

”). (Refer to Figure 5 and 6.)

3, 4 - Wire electrical wall Receptacle

CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.

Protection cover

FIGURE 3

FIGURE 4

Range rating, watts

Specified rating

of power-supply-

cord kit, amperes

120/240 volts

3-wire

8,750 - 16,500

16,501 - 22,500

120/208 volts

3-wire

7,801 - 12,500

12,501 - 18,500

40 or 50A

50

Diameter (inches) of Range

connection Opening

Conduit

1

1

/

8

1

3

/

8

Power cord

1

3

/

8

1

3

/

4

Specified power-supply-cord kit rating

ELECTRICAL CONNECTION

REQUIREMENTS

This appliance must be installed and grounded on a branch

circuit by a qualified technician in accordance with the

National Electrical code ANSI/NFPA NO. 70 - latest edition.
All wiring should conform to Local and NEC. This range

requires a single-phase, 3 wire, A.C 120/208V or 120/240V 60Hz

electrical system. Use only a 3-conductor or a 4-conductor

UL-listed range cord with closed-loop terminals, open-end

spade lugs with upturned ends or similar termination. DO

NOT install the power cord without a strain relief.
A range cord rated at 40 amps with 120/240 minimum volt

range is required. If a 50 amp range cord is used, it should

be marked for use with 1

3

8

” diameter connection openings.

This appliance may be connected by means of conduit or

power cord. If conduit is being used, go to page 7 for 3 wire

conduit connections or page 8 for 4 wire conduit connections.

WARNING

• New branch-circuit installations (1996 NEC)

for mobile homes, recreational vehicles, and

installations where local codes do not allow

grounding through the neutral wire require a

4-conductor UL listed range cord or 4 wire

conduit connection.

• Power supply cord and plug should not be

modified. If it will not fit the outlet, have a proper

outlet Installed by a qualified electrician.

• Using an extension cord to connect the power is

prohibited. The way to connect the power cord

and plug directly is strongly recommended.

• Electrical ground is required on this appliance.

• You should make sure that the power cord is

not pinched by the range or heavy objects.

- Failure to do so can result in serious burns or electrical shock.

Gloves

Safety Glasses

Tape Measure

Pencil

Rear filler & 2 Screws

(LSE Series only)

Protection cover

Protection cover

FIGURE 5

FIGURE 6

Remove the Conduit connection plate

Assemble the

strain relief hole

Reinstall the Cord/Conduit connection plate

WARNING

• You never remove the protection cover

covering the rear of lower oven.

- Failure to do so can result in serious damage to power cord.

The damage causes serious burns and electric shock.

Gloves

Safety Glasses

Tape Measure

Pencil

Rear filler & 2 Screws

(LSE Series only)

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)