Part 3 electrical connections, Warning, Wire connection with a power supply cord – LG LDE3017SW User Manual

Page 7: Install the power cord as follows

Advertising
background image

7

ENGLISH

Part 3

ELECTRICAL CONNECTIONS

FIGURE 7

FIGURE 8

3-wire connection

Assemble the strain relief

to the 1

3

/

8

” opening in

Conduit connection plate

Separate Strain Relief

before installation

3-wire connection with a power supply cord

WARNING

• The middle (neutral or ground) wire of a 3

wire power cord or a 3 wire conduit has to

be connected to the middle post of the

main terminal block. The remaining two

wires of the power cord or conduit have to

be connected to the outside posts of the

main terminal connection block.

- Failure to do so can result in electrical shock, severe

personal injury or death.

Gloves

Safety Glasses

Tape Measure

Pencil

Rear filler & 2 Screws

(LSE Series only)

Install the power cord as follows:

For power cord installations, Hook the strain relief

over the power cord hole (1

3

/

8

”) located below the rear

of lower oven. Insert the power cord through the

strain relief and tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1. Remove the lower 3 screws from the terminal block

and retain them. (Refer to Figure 8.)

2. Insert the 3 screws through each power cord

terminal ring and into the lower terminals of the

terminal block.

Make sure that the center wire (white/neutral) is

connected to the center lower position of the

terminal block.

3. Tighten 3 screws securely into the terminal block.

Do not remove the ground strap connections.

4. Go to page 10.

Advertising