Operation, Auxiliary power, Wire welding-cv – Lincoln Electric VANTAGE 500 (CE) IM894-B User Manual

Page 25: Arc gouging

Advertising
background image

Carbon Diameter

Current Range (DC, electrode

positive)

1/8"(3.2mm)

60-90 Amps

5/32"(4.0mm)

90-150 Amps

3/16"9(4.8mm)

200-250 Amps

1/4"(6.4mm)

300-400 Amps

3/8"(10.0mm)

400-Max.Amps

AUXILIARY POWER:

Start the engine and set the IDLER control switch to

the desired operating mode. Full power is available

regardless of the welding control settings providing no

welding current is being drawn.

Simultaneous Welding and Auxiliary Power Loads

The auxiliary power ratings are with no welding load.

Simultaneous welding and power loads are specified

in Table B.5.

VANTAGE® 500 (CE) Extension Cord Length Recommendations

(Use the shortest length extension cord possible sized per the following table.)

Current

(Amps)

15

20

15

20

44

Voltage

Volts

120

120

240

240

240

Load

(Watts)

1800

2400

3600

4800

9500

30

60

(9)

(18)

40

30

75

60

(12)

(9)

(23)

(18)

75

50

150

100

50

(23)

(15)

(46)

(30)

(15)

125

88

225

175

90

(38)

(27)

(69)

(53)

(27)

175

138

350

275

150

(53)

(42)

(107)

(84)

(46)

300

225

600

450

225

(91)

(69)

(183)

(137)

(69)

Maximum Allowable Cord Length in ft. (m) for Conductor Size

Conductor size is based on maximum 2.0% voltage drop.

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

VANTAGE

®

500 (CE)

B-7

OPERATION

B-7

This will keep the "Solid State" contactor open and provide a

"cold" electrode until the Amptrol or Arc Start Switch is pressed.

When using the TIG Module, the OUTPUT CONTROL on the

VANTAGE® 500 (CE) is used to set the maximum range of the

CURRENT CONTROL on the TIG Module or an Amptrol if con-

nected to the TIG Module.

NOTE: The TIG process is to receive a low voltage welding

process. There is no difference in operation with the

VRD “On” or “Off” for this mode. For indicator light oper-

ation, see table B.1.

WIRE WELDING-CV

Connect a wire feeder to the VANTAGE® 500 (CE) according

to the instructions in INSTALLATION INSTRUCTIONS Section.

The VANTAGE® 500 (CE) in the CV-WIRE mode, permits it to

be used with a broad range of flux cored wire (Innershield and

Outershield) electrodes and solid wires for MIG welding (gas

metal arc welding). Welding can be finely tuned using the ARC

CONTROL. Turning the ARC CONTROL clockwise from –10

(soft) to +10 (crisp) changes the arc from soft and washed-in to

crisp and narrow. It acts as an inductance/pinch control. The

proper setting depends on the procedure and operator prefer-

ence. Start with the dial set at 0.

NOTE: In the CV-Mode with VRD “On”, the OCV(Open Circuit

Voltage) is not reduced. For indicator light operation,

see table B.1.

ARC GOUGING

The VANTAGE® 500 (CE) can be used for arc gouging.

For optimal performance, set the MODE switch to ARC

GOUGING.

TABLE B.5

TABLE B.6

WELDING OUTPUT

(AMPS)

NOT WELDING

100

200

300

400

450

Max.

AUXILIARY POWER OUTPUT

(WATTS)

14,500

11,100

8,900

4,900

700

0

0

AUXILIARY POWER OUTPUT

(AMPS @ 400V, 3-PHASE)

21.0

17.5

12.8

7.1

1.0

0

0

SIMULTANEOUS WELDING AND AUXILIARY POWER OUTPUT

Set the OUTPUT CONTROL knob to adjust output

current to the desired level for the gouging electrode

being used according to the ratings in the following

Table B.4.

TABLE B.4

The ARC CONTROL is not active in the ARC GOUG-

ING Mode. The ARC CONTROL is automatically set

to maximum when the ARC GOUGING mode is

selected which provides the best ARC GOUGING per-

formance.

NOTE: With the VRD switch in the “ON” position there

is no output in the Arc Gouging Mode. For indicator

light operation, see table B.1.

Advertising