Troubleshooting, Caution – Lincoln Electric IDEALARC R3R 375-I User Manual

Page 18

Advertising
background image

E-6

TROUBLESHOOTING

E-6

IDEALARC® R3R 375-I, 500-I AND 600-I

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

L. Optional remote current control

not functioning. See
Troubleshooting , Section C
before connecting.

1. Current control switch in the

wrong position.

2. Leads 75, 76 and 77 not con-

nected to correct numbers on
models with terminal strip.

3. Remote control leads broken.

4. Remote control potentiometer

open.

5. Lead or connection in current

control circuit open.

6. Control PC board plug discon-

nected or loose.

7. Control circuit problems.

1. Place switch in “remote” (

)

position.

2. Correct connection.

3. Repair broken leads.

4. See Troubleshooting, Section C.

5. Connect or repair.

6. Connect plug.

7. See SCR Troubleshooting,

Section K.