INSTALLATION

IDEALARC® R3R 375-I, 500-I AND 600-I

A-1

INSTALLATION

FALLING EQUIPMENT can cause
injury.

• Do not lift this machine using lift

bail if it is equipped with a heavy

accessory such as trailer or gas cylinder.

• Lift only with equipment of adequate lifting

capacity.

• Be sure machine is stable when lifting.

The machine should be located in a clean, dry place
where there is free circulation of clean air, such that air
movement entering the front and exiting the back will
not be restricted. Dirt and dust that can be drawn into
the machine should be kept to a minimum. Failure to
observe these precautions can result in excessive
operating temperatures and nuisance shutdown of the
machine.

The Idealarc R3R welders can be stacked three high
when the following precautions are observed:

1. Be sure the bottom machine is on a firm, level sur-

face suitable for the total weight [up to 1340 pounds
(608 kg)] of the stacked machines.

2. Stack the machines with the fronts flush. Be certain

the pins on the top front corners of the lower
machines fit through the holes in the base rails of
the upper machines.

3. No unit heavier than the bottom unit should be

stacked on top of it. For example, an R3R 500-I
shall not be slacked on top of an R3R 400-I, but an
R3R 400-I may be stacked on top of an R3R 500-I.

INPUT POWER CONNECTION

ELECTRIC SHOCK can kill.

• Have an electrician install and ser-

vice this equipment.

• Turn the input power off at the fuse

box before working on equipment.

• Do not touch electrically hot parts.

Remove the rear access panel. Connect the three
phase input power to the three line terminals on the
input contactor, and the earth ground lead to the
ground stud marked with the

symbol. Install the

reconnect panel for the proper input voltage per the
diagram pasted inside the access panel cover.

DUTY CYCLE

The maximum output rating of this welder is at a 35%
duty cycle. Duty cycle is based on a ten minute period.
Therefore, the welder can be operated at the maximum
rated output for 3.5 minutes out of every 10 minute
period without overheating.

Failure to follow these instructions can cause immedi-
ate failure of components within the machine.

When powering welder from a generator be sure to
turn off welder first, before generator is shut down,
in order to prevent damage to welder!
------------------------------------------------------------------------

OUTPUT CONNECTIONS

With the machine power switch off, the output leads
are connected to the Magnum™ Twist-Mate™ output
terminals marked “–” and “+”. They are located at the
lower right and lower left corners of the front panel.
Strain relief for the electrode and work cables is pro-
vided by routing the leads through the rectangular
holes in the base before the connections to the output
terminals are made. Twist-Mate Lead plugs must be
installed to the output cables before connections can
be made to the power source. See S18737 instructions
included with the plugs.

Theommended output cable sizes can be found in the
Table below.

WARNING

WARNING

Copper Wire Size

Input

Type 75°C in Conduit

Super Lag

R3R

Volts

Amps

3 Input

1 Ground

Fuse Size

Welder 50/60 Hz

Input

Wires

Wire

in Amps

220

67

8

8

80

375-I

380

39

10

10

60

440

34

10

10

40

220

90

6

6

125

500-I

380

52

8

8

80

415-440

45

10

10

60

220

103

4

6

150

600-I

380

60

8

8

90

440

52

8

8

70

Machine Up to 100 ft. 100 to 150 ft. 150 to 200 ft. 200 to 250 ft.

Size

(30 m)

(30 – 46 m)

(46 – 61 m)

(61 – 76 m)

375-I

1/0 (54 mm

2

) 1/0 (54 mm

2

)

2/0 (68 mm

2

)

3/0 (86 mm

2

)

500-I

2/0 (68 mm

2

) 2/0 (68 mm

2

)

3/0 (86 mm

2

) 4/0 (108 mm

2

)

600-I

2/0 (68 mm

2

) 3/0 (86 mm

2

)

3/0 (86 mm

2

) 4/0 (108 mm

2

)

CAUTION