INSTALLATION

A-7

A-7

LN-9 GMA and LN-9F GMA Wire Feeder

FIGURE A.5 – CONNECTION OF LN-9 GMA TO DC-600 POWER SOURCES

Above diagram shows electrode connected positive. To change polarity, turn power off, reverse the electrode and work leads at the
power source and position the switch on power source to proper polarity.

For optimum performance with the LN-9 GMA, DC-600’s with codes 8288 and above are preferred.

N.B. Welding cables must be of proper capacity for the current and duty cycle of immediate and future applications.

N.C. Extend lead #21 using #14 or larger insulated wire physically suitable for the installation. An S16586-[ ] remote voltage sensing

work lead is available for this purpose. Connect it directly to the work piece keeping it electrically separate from the welding work
lead circuit and connection. For convenience, this extended #21 lead should be taped to the welding work lead. (This extended
#21 lead connection replaces the need to employ the remote work lead accessory on LN-9’s which have a direct work lead jack.)

N.D. Tape up bolted connection.

N.E. Connect the LN-9 GMA control cable ground lead to the frame terminal marked near the power source terminal strip. The

power source must be properly grounded.

N.G. The LN-9 GMA voltage control jumpers must be connected as follows:

White jumper on voltage board to pin “S”.
Blue jumper on voltage board (Later units only) or on start board (Earlier units) to pin “B”.

N.H. For DC-600 Codes below 8200 connect a jumper from “N” to “P” on LN-9 GMA only. There is no NPS terminal strip on codes

above 8200.

WARNING

• Turn off input power to the welding

power source using the disconnect
switch at the fuse box before connect-
ing the wire feeder

• Only qualified persons should install,

use or service this machine.

ELECTRIC SHOCK

can kill.