Troubleshooting, Caution – Lincoln Electric IM355-C LN-9 GMA User Manual

Page 60

Advertising
background image

TROUbLESHOOTING

E-6

E-6

LN-9 GMA and LN-9F GMA Wire Feeder

PRObLEMS
(SYMPTOMS)

Variable or "hunting" arc.

POSSIbLE AREAS OF
MISADJUSTMENT(S)

1. Check for worn or incorrect sized

contact tip. Replace tip if
necessary.

2. Check for worn or undersized

work cables. Repair or replace if
necessary.

3. Check

for

loose

electrode

connections.

Be

sure

the

following connections are tight:
Electrode cable to wire feeder
and power source, work cable to
power source and work, gun
cable to wire feeder contact
block, gun nozzle to body, and
contact tip to nozzle.

4. Check whether the Voltage

Control Response is properly set
for the power source and the
process. See the topic “Voltage
Control Response”

in the

Operation section.

RECOMMENDED
COURSE OF ACTION

If all recommended possible
areas of misadjustment have
been checked and the problem
persists, contact your local
Lincoln Authorized Field Service
Facility.

If for any reason you do not understand the test procedures or are unable to perform the necessary tests/repairs
safely, contact your local authorized field service facility before you proceed.

WELDING PRObLEMS

CAUTION

Observe Safety Guidelines
detailed in the beginning of this manual.

TROUbLESHOOTING GUIDE

Advertising