Installation, Warning caution – Lincoln AIR VANTAGE IM985 User Manual

Page 18

Advertising
background image

A-10

INSTALLATION

AIR VANTAGE® 500 KUbOTA

A-10

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE AIR VAN-
TAGE® 500 KUbOTA

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the AIR VANTAGE®
500 KUBOTA, refer to the NA-3 Welding System
instruction manual. The connection diagram for the
LN-8 can be used for connecting the NA-3.

• Set the Wire Feeder Voltage Switch to 115V.

CONNECTION OF MAGNUM SC SPOOL
GUN TO THE AIR VANTAGE® 500 KUbO-
TA (SEE SECTION F)

CONNECTION OF PRINCE XL SPOOL
GUN TO THE AIR VANTAGE® 500 KUbO-
TA

Connection of the Prince XL Spool Gun requires the
use of the K1849-1 Adapter Module.

1. Shut the Welder off.

2. For electrode Positive, connect the electrode

cable to the "+" terminal of the welder and work
cable to the "-" terminal of the welder. For elec-
trode Negative, connect the electrode cable "-" ter-
minal of the welder and work cable to the "+" ter-
minal of the welder.

3. Connect the Control Cable of the Spool Gun to the

Adapter Module and connect the Control Cable of
the Adapter Module to the Welder.

4. Connect the Gas Hose.

5. Set the MODE switch to the "CV-WIRE " position.

6. Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON".

7. Set the "ARC CONTROL" knob to "0" initially and

adjust to suit.

8. Set the "IDLE" switch to the "High" position

Spool Gun (K487-25) and Cobramatic to AIR VAN-
TAGE® 500 KUbOTA

• Shut the welder off.

• Connect per instructions on the appropriate connec-

tion diagram in Section F.

CONNECTION OF THE LN-25 TO THE AIR
VANTAGE® 500 KUbOTA.

Shut off welder before making any electrical con-
nections.

--------------------------------------------------------------------------------

The LN-25 with or without an internal contactor may
be used with the AIR VANTAGE® 500 KUBOTA . See
the appropriate connection diagram in Section F.

1. Shut the welder off.

2. For electrode Positive, connect the electrode

cable from the LN-25 to the "+" terminal of the
welder and work cable to the "-" terminal of the
welder. For electrode Negative, connect the elec-
trode cable from the LN-25 to the "-" terminal of
the welder and work cable to the "+" terminal of
the welder.

3. Attach the single lead from the front of the LN-25

to work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire
feeder motor; it does not carry welding current.

4. Set the MODE switch to the "CV-WIRE " position.

5. Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON"

6. Set the "ARC CONTROL" knob to "0" initially and

adjust to suit.

7. Set the "IDLE" switch to the "AUTO" position.

When not welding, the AIR VANTAGE® 500 KUB-
OTA engine will be at the low idle speed. If you
are using an LN-25 with an internal contactor, the
electrode is not energized until the gun trigger is
closed.

8. When the gun trigger is closed, the current sens-

ing circuit will cause the AIR VANTAGE® 500
KUBOTA engine to go to the high idle speed, the
wire will begin to feed and the welding process
started. When welding is stopped, the engine will
revert to low idle speed after approximately 12
seconds unless welding is resumed.

If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
AIR VANTAGE® 500 KUbOTA is started.

------------------------------------------------------------------------

WARNING

CAUTION

Advertising