Operation, B-4 case front controls – Lincoln Electric POWER WAVE IM713-B User Manual

Page 21

Advertising
background image

B-4

OPERATION

POWER WAVE® 655/R

B-4

CASE FRONT CONTROLS

All operator controls and adjustments are located on

the case front of the Power Wave®. (See Figure B.1)

1. POWER SWITCH: Controls input power to the

Power Wave®.

2. STATUS LIGHT: A two color light that indicates

system errors. Normal operation is a steady green

light. Error conditions are indicated per table 4.

NOTE: The robotic Power Wave’s® status light will

flash green, and sometimes red and green, for up to

one minute when the machine is first turned on. This

is a normal situation as the machine goes through a

self test at power up.

TABLE 6

Light

Condition

Steady Green

Blinking

Green

A l t e r n a t i n g

G r e e n

a n d

Red

Steady Red

Blinking Red

Meaning

System OK. Power source communicating normal-

ly with wire feeder and its components.

Occurs during a reset, and indicates the PW-

655/R is mapping (identifying) each component

in the system. Normal for first 1-10 seconds

after power is turned on, or if the system con-

figuration is changed during operation.

Non-recoverable system fault. If the PS

Status light is flashing any combination of

red and green, errors are present in the PW-

655 /R. Read the erro r code be fore the

machine is turned off.

Error Code interpretation through the Status

light is detailed in the Service Manual.

Individual code digits are flashed in red with

a long pause between digits. If more than

one code is present, the codes will be sepa-

rated by a green light.

To clear the error, turn power source off, and

b a c k o n t o r e s e t . S e e T r o u b l e s h o o t i n g

Section.

Not applicable.

Not applicable.

3. HIGH TEMPERATURE LIGHT (thermal overload):

A yellow light that comes on when an over temper-

ature situation occurs. Output is disabled until the

machine cools down. When cool, the light goes out

and output is enabled.

4. 10 AMP WIRE FEEDER CIRCUIT BREAKER:

Protects 40 volt DC wire feeder power supply.

5. 10 AMP AUXILIARY POWER CIRCUIT BREAKER:

Protects 110 volt AC case front receptacle auxiliary

supply.

6. LEAD CONNECTOR S2 (SENSE LEAD)

7. 5-PIN ARC LINK S1

8. 5-PIN DEVICENET CONNECTOR S5

9. I / O CONNECTOR

10. NEGATIVE STUD

11. INTERFACE CONNECTOR S6

12. POSITIVE STUD

13. AUXILIARY OUTPUT

-

+

POWERWAVE

STUD

SENSE

5
LINK

5

Case Front Layout

Power Wave 655/R (Domestic/Canadian Version)

S6

1

3

2

11

12

4

13

5

9

10

8

7

6

FIGURE B.1