Troubleshooting, Caution – Lincoln Electric POWER WAVE IM713-B User Manual

Page 31

Advertising
background image

E-6

TROUBLESHOOTING

E-6

POWER WAVE® 655/R

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The PowerWave is triggered to weld,

but there is no output.

The feeder will not cold inch wire

Arc loss fault on robot

1. Check for fault signals from the

I/O connector. Possible faults are

l a c k o f w a t e r f l o w / w a t e r f l o w

turned off.

1. Check for fault signals from the

I/O connector. Possible faults are

lack of water flow/ water cooler

turned off.

1. Possibly caused by wire feeding

problem.

2 Problem - Conduit leading to the

wire feeder has bends or twists,

which can reduce the wire feed

speed.

S o l u t i o n - R e m o v e b e n d s a n d

twists from conduit.

3. Problem – Conduit leading up to

the wire feeder from the wire reel

is too long.

Solution – Use a shorter length of

conduit.

WELDING PROBLEMS

If all recommended possible areas

of misadjustments have been

checked and the problem persists,

contact your local Lincoln

Authorized Field Service Facility.

Advertising