INSTALLATION

COMMANDER 300

A-8

CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS

Shut off welder before making any electrical connec-
tions.

------------------------------------------------------------------------

CONNECTION OF THE LN-25 TO THE
COMMANDER 300

The LN-25 with or without an external contactor may
be used with the Commander 300. See the appropri-
ate connection diagram in the ACCESSORIES section.

NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the Commander 300.

a. Shut the welder off.

b. For electrode Positive, connect the electrode cable

from the LN-25 to the “+” terminal of the welder and
work cable to the “-” terminal of the welder. For
electrode Negative, connect the electrode cable
from the LN-25 to the “-” terminal of the welder and
work cable to the “+” terminal of the welder.

c. Attach the single lead from the front of the LN-25 to

work using the spring clip at the end of the lead.
This is a sense lead to supply current to the wire
feeder motor; it does not carry welding current.

d. Set the SELECTOR switch to the “WIRE WELD-

ING” position.

e. Set the “WELDING TERMINALS” switch to “WELD-

ING TERMINALS ALWAYS ON”

f. Adjust the “ARC CONTROL” knob to desired crisp-

ness. Generally, welding is best if the “ARC CON-
TROL” is set to SOFT for MIG and CRISP for
Innershield.

g. Set the “IDLE” switch to the “AUTO” position. When

not welding, the Commander 300 engine will be at
the low idle speed. If you are using an LN-25 with
an internal contactor, the electrode is not energized
until the gun trigger is closed.

If you are using an LN-25 without an internal contactor,
the electrode will be energized when the Commander
300 is started.

------------------------------------------------------------------------

h. When the gun trigger is closed, the current sensing

circuit will cause the Commander 300 engine to go
to the high idle speed, the wire will begin to feed
and the welding process started. When welding is
stopped, the engine will revert to low idle speed
after approximately 12 seconds unless welding is
resumed.

CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 300

a. Shut the welder off.

b. Connect the LN-7 or LN-8 per instructions on the

appropriate connection diagram in Section 4.

c. Set the “LOCAL /REMOTE” switch to “REMOTE” for

the LN-8 or LN-7 with a K857 (or K857-1) remote
voltage control cable attached; “LOCAL” for LN-7
with no remote voltage control.

d. Set the “WIRE FEEDER VOLTMETER” switch to

either “+” or “-” as required by the electrode being
used.

e. Set the “SELECTOR” switch to the “WIRE WELD-

ING” position.

f. Adjust the “ARC CONTROL” knob to desired

Crispness. SOFT for MIG - CRISP for Innershield.

g. Set the “WELDING TERMINALS” switch to the

“WELDING TERMINALS”

REMOTELY CON-

TROLLED” position.

h. Set the “IDLE” switch to the “HIGH” position. When

not welding, the Commander 300 engine will be at
the low idle speed.