Technical Data

Interfaces

Compliant with the ITU-T Recommendations:

General

G.707 (includes G.708 and G.709)

Equipment

G.781, G.782, G.783, G.784, G.813

Physical interface

G.957 & G.691 for optics and G.703 for

electrical interfaces.

Performance requirements

G.823, G.825, G.826

Mapping Structure

AU4, AU-3 to TU-3, TU-3 & TU-12

(TU-11), VC-4, VC-3 and VC-12

Electrical Interfaces

1.5 Mbps a-synchronous/byte-synchronous

63 (DS-1) interfaces per circuit pack

2 Mbps a-synchronous/byte-synchronous

63 (E1) interfaces per circuit pack

34 / 45-Mbps and 45 Mbps a-synchronous

12 (E3/DS-3) interfaces per circuit pack

140 Mbps/STM-1 electrical intra-station

4 (E4/STM-1) interfaces per circuit pack

Optical Interfaces

Ethernet 10/100 BASE-T & (ML-PPP) 8 interfaces per circuit pack

STM-0 (51840 kbps) interface

12 x interfaces per circuit pack

STM-1/OC-3 (155520 kbps) interface

4 x (S-1.1 & L-1.2) interfaces per circuit

pack

STM-4/OC-12 (622080 kbps) interface

1 x (S-4.1 & L-4.2) interface per circuit

pack

STM-16 (2 488 320 kbps) interfaces

1 x (L-16.1, L-16.2 & L-16.3) interface

per circuit pack

Optical Booster/Pre-amplifier

1 x (U-16.2/3) interface per circuit pack

Optical Booster

1 x (V-16.2/3) interface per circuit pack

OLS 80G (DWDM) interworking

1 x interface per circuit pack, 16 different

wavelengths (1549 - 1559 nm )

OLS 400G (DWDM) Interworking

1x interface per circuit pack, 80 different

wavelengths (1530 - 1565 nm )

Data interfaces:

Six user selectable datachannels

User can select out of E1, E2, F1, F2

and NU bytes (4xG.703 and 2xV.11)

Standard External clock interfaces

Two programmable Input/Output

station clock interfaces: 2048 kHz

(G703.10) or 2048 kbps

(G703.6), 75 or 120 W

Bandwidth Management

System capacity:

VC-12: 504 x 1.5 Mbps, 504 x 2 Mbps,

VC-3: 48 x 34 Mbps, 96 x 45 Mbps,

96 x STM-0,

VC-4: 32 x 140 Mbps, 32 x STM-1 or

8 x STM-4

Complete VC-4 Cross-connecting

Higher Order Cross-connect size 64 x 64 VC-4

Lower Order Cross-connect currently 16x16 and 32 x 32 VC-4

Fixed Cross-Connect for 0x1 and 0x2 Terminal Applications

Uni & Bi-directional Cross-connecting

Broadcast connections type VC-n

VC-4-4c Continuos Concatenation

Higher Order and Lower Order broadcast functionality 1:N (N£9)

Protection access (LPT) on

MS-SPRing

Scalable MS-SPRing

Drop & Continue

Performance requirements

Jitter on STM-N interfaces

G.813, G.825

Jitter on PDH interfaces

G.823, G.783

Error Performance

G.826

Performance monitoring

G.784, G.826