7: Network, Serial Line, and Tunnel Settings

EDS Device Servers User Guide

65

Tunnel – Packing Mode Page

Tunnel – Packing
Mode Page
Settings

Description

Mode

Select the method used to pack data. Choices are:

Disabled = data is never packed. (default)

Timeout = data is sent after the timeout elapses.

Send Character = data is sent when the send character is read on
the serial line.

Timeout

Enter the maximum number of milliseconds to wait before sending
queued data across the network. Default is 1000 milliseconds.

Threshold

Enter the queued data limit that, when reached, immediately sends
queued data to the network. Default is 512 bytes.

Send Character

Enter the send character. When this character is read on the serial
line, it forces the queued data to be sent immediately. Default is
<none>.

Trailing Character

Enter the trailing character. This character is inserted into the
outgoing data stream immediately after the send character. Default is
<none>.