Programming – Lennox International Inc. 43558 User Manual

Page 11

Advertising
background image

20

20

PROGRAMMING

Option Menu (continued)

Stage 1 SPAN selection

or

to change the SPAN setting to 1, 2, or 3. The

factory setting is 2. Setting 1 will cause shorter cycle times. Setting 3
will cause longer cycle times.

Stage 2 SPAN selection

or

to change the SPAN setting to 1, 2, 3, 4, 5 or 6.

The factory setting is 2. Lower settings will cause the 2nd stage to turn
on sooner. Higher settings will cause the 2nd stage to turn on later.

NOTE:

Refer to the SPAN section on page 48 for more information on SPAN settings.

Auto Season Changeover Deadband selection

or

to change the deadband between 3, 4, 5 or 6

°

F,

The factory setting is 5. (

°

C are about 1/2

°

F)

NOTE:

Refer to the Auto Season Changeover section on page 43 for more information.

Span Stg1

Span Stg2

option

6

option

7

option

8

Recovery

System

41653_model43558.pmd

21

Auto Recovery selection

or

to enable “YES” or disable “NO” the Auto

Recovery Mode. The factory setting is “YES.”

■ To change between Heat or Cool recovery modes.

NOTE:

Auto Recovery is one of the ENERGY STAR

®

features of this thermostat. Refer to the Auto Recovery section on

pages 49-50 for more information.

LCD Contrast adjustment

or

to change the LCD contrast between 0 and 9.

Lower numbers lighten the display. Higher numbers darken the display.
The factory setting is 5.

system

option

9

Recovery

System

option

10

LC D

Advertising