Advanced controller programming (cont.), Mid-travel stop position, Anti-tailgate enable – Linear SWR User Manual

Page 20: Motor type selection

Advertising
background image

SWR

• SWC • SWD Swing Gate Operator Installation Guide

- 18 -

227965 Revision X22 8-11-2011

Advanced Controller Programming (Cont.)

Mid-travel Stop Position

The Controller can be programmed so the gate will stop at a mid-travel
point instead of fully opening. This can be useful in installations where a
large gate, that takes a long time to open and close fully, only needs to
be opened partway to allow traffi c to pass.

The factory default sets the Controller for full open operation. Alternately,
the Controller can be programmed to open for 1 to 99 seconds then stop,
before reaching the open limit.

When a Mid-travel Stop Position time has been programmed, the gate
will still fully open if the Fire Department input is triggered, if the OPEN
button is held down beyond the Mid-travel Stop Position, or a close
obstruction or reverse loop input is triggered.

NOTE: The Mid-travel Stop feature is disabled when dual gate

operation is enabled for paired units.

Anti-tailgate Enable

The factory default sets the Anti-tailgate Enable to OFF. With this setting,
during a gate cycle, after the shadow loop has been triggered by the
vehicle and then has cleared after the vehicle passes, the Auto Close
Timer or a CLOSE command is required to begin closing the gate.

If the Anti-tailgate Enable is set to ON, the gate will close immediately
as soon as the shadow loop has cleared. Any subsequent shadow loop
triggers while the gate is closing will stop the gate. When the shadow loop
clears, the gate will continue closing.

Motor Type Selection

The factory sets the default for the Controller to match the type of motor in
the operator. If required, change the motor selection option to a different
type of motor used in the operator. The options available are:

• AC Motor Only
• DC Motor Only with Mechanical Braking
• DC Motor with Electronic Soft Start/Stop
• 3 Phase AC Motor
• AC Motor with DC Motor Backup with Mechanical Braking
• AC Motor with DC Motor Backup with Electronic Soft Start/Stop

FUNCTION

SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS

MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MID-TRAVEL

STOP POSITION

"MT"

FUNCTION

ANTI-TAILGATE ENABLE OFF
GATE REQUIRES AUTO OR MANUAL CLOSE

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

ANTI-TAILGATE

ENABLE

"AT"

ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS

FUNCTION

DC MOTOR ONLY WITH BRAKING

AC MOTOR ONLY

DC MOTOR WITH SOFT START/STOP

AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH BRAKING

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MOTOR TYPE

SELECTION

NOTE: SELECTION

MUST MATCH

MOTOR BOARD!

"MO"

3 PHASE AC MOTOR

AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH SOFT START/STOP

Advertising
This manual is related to the following products:

SWD, SWC