Important – Linear XR-16 User Manual

Page 2

Advertising
background image

IN

STR

,I

N

ST

L,

XR

-1

6

LINEAR P/N: 2

1515

7 B

MAT

E

R

IAL

: 20

LB.

M

EAD

BON

D

SIZE: 8

.500

" X 11

.000

"

SC

ALE:

1-1

IN

K:

BL

ACK

SI

D

E

2

OF 2

(B

ACK)

8.

TYPICAL WIRING CONNECTIONS

9.

SET OPTION JUMPERS

10. SET SYSTEM CODE

11. SET STATUS OPTIONS

12. SET TRANSMITTER CHANNELS

13. TEST THE SYSTEM

14. EXAMPLE HOOK-UPS

LINEAR LIMITED WARRANTY

This Linear product is warranted against defects in material and workmanship
for twelve (12) months. The Warranty Expiration Date is labeled on the product.
This warranty extends only to wholesale customers
who buy direct from Linear or
through Linear’s normal distribution channels. Linear does not warrant this product
to consumers.
Consumers should inquire from their selling dealer as to the nature of
the dealer’s warranty, if any. There are no obligations or liabilities on the part of
Linear LLC for consequential damages arising out of or in connection with use
or performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installation, or reinstallation.
All
implied warranties, including implied warranties for merchantability and implied
warranties for fitness, are valid only until Warranty Expiration Date as labeled on the
product. This Linear LLC Warranty is in lieu of all other warranties express or
implied.
All products returned for warranty service require a Return Product Authorization
Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA#
and other important details.

IMPORTANT !!!

Linear radio controls provide a reliable communications link and fill an important need
in portable wireless signaling. However, there are some limitations which must be
observed.
WARNING: THIS PRODUCT IS NOT TO BE USED IN LIFE SAFETY

APPLICATIONS. FCC Rules allow unlicensed high-power transmissions at
or near the operating frequency of this product which may interfere with,
or even disable, normal operation of this radio device.

✶ For U.S. installations only: The radios are required to comply with FCC Rules

and Regulations as Part 95 Radio Control devices. As such, they have limited
transmitter power and therefore limited range.

✶ A receiver cannot respond to more than one transmitted signal at a time and

may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.

✶ Changes or modifications to the device may void FCC compliance.

✶ Infrequently used radio links should be tested regularly to protect against

undetected interference or fault.

✶ A general knowledge of radio and its vagaries should be gained prior to acting as

a wholesale distributor or dealer, and these facts should be communicated to the
ultimate users.

Copyright © 2004 Linear LLC

215157 B

INSTALL END-OF-LINE RESISTORS
IF REQUIRED BY ALARM PANEL

TYPICAL 8-ZONE

ALARM CONTROL PANEL

ZONE 1

COMMON

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

ZONE 8

COMMON

COMMON

COMMON

AUXILIARY
POWER

OUTPUTS PROGRAMMED
FOR NORMALLY OPEN

CH1

CH2

CH3

CH4

GND

CH5

CH6

CH7

CH8

GND

CH9

CH10

CH11

CH12

GND

CH13

CH14

LOW BAT

STS ALM

GND

N/O

N/C

COM

+12 VDC

GND

CH15

CH16

GND

RELAY

XR-16 RECEIVER

ZONE 8 IS BEING USED
TO REPORT TROUBLE

RECEIVER CHANNELS 8-16
ARE UNUSED IN THIS EXAMPLE

EXAMPLE OF
DRIVING A RELAY
FROM XR-16 OUTPUT

NOISEMAKER
ACTIVATED BY
XR-16 RELAY

+

THE XR-16 RELAY OUTPUT CAN BE
PROGRAMMED TO ACTIVATE WITH
ANY SIGNAL OR ONLY ALARM SIGNALS

OUTPUT

OPTION

JUMPER (JP2)

RELAY

OPTION

JUMPER (JP1)

1 2 3

1 2 3

OUTPUT

OPTION

RELAY

OPTION

1 & 2 = ALL OUTPUTS
NORMALLY OPEN

1 & 2 = RELAY WILL ACTIVATE
ON ALARMS & TROUBLE

1 2 3

1 2 3

2 & 3 = ALL OUTPUTS

NORMALLY CLOSED

2 & 3 = RELAY WILL

ACTIVATE ON ALARMS ONLY

OUTPUT

OPTION

RELAY

OPTION

XR-16 RECEIVER

SWITCH "A"

SWITCH "B"

SET SYSTEM CODE SWITCHES "A" & "B" IN THE
RECEIVER TO MATCH SYSTEM CODE SWITCHES
"A" & "B" IN ALL OF THE SYSTEM'S TRANSMITTERS

SYSTEM CODE SWITCHES

AVOID SETTING SYSTEM CODE SWITCHES
ALL "ON", ALL "OFF", OR IN ALTERNATING
"ON"/"OFF" PATTERNS

XR-16 RECEIVER

LEFT DIPSWITCH

SWITCHES 1-8

CHANNELS 1-8

RIGHT DIPSWITCH

SWITCHES 1-8

CHANNELS 9-16

SET STATUS OPTION SWITCHES "ON" FOR EACH
RECEIVER CHANNEL THAT WILL REQUIRE STATUS
REPORTS

STATUS OPTION SWITCHES

ANY CHANNEL WITH ITS STATUS OPTION SWITCH "ON"
WILL EXPECT HOURLY STATUS REPORTS FROM
TRANSMITTERS PROGRAMMED TO THAT CHANNEL

IF STATUS REPORTS ARE NOT RECEIVED FOR THAT
CHANNEL FOR FOUR HOURS, THE STATUS ALARM
OUTPUT WILL ACTIVATE (THE RELAY CAN ALSO
ACTIVATE IF SELECTED)

2

1

3
4
5
6
7
8
9

10
11
12
13
14
15
16

RX

CH. #

BANK 1

BANK 2

BANK 3

BANK 4

TX

CH. #

2

1

3
4
1
2
3
4
1
2
3
4
1
2
3
4

EVERY FOUR RECEIVER CHANNELS CREATE ONE
RECEIVER BANK

SINGLE-CHANNEL TRANSMITTERS:

SET THE RECEIVER CHANNEL NUMBER (1-4) AND
BANK NUMBER (1-4) ON THE OPTION SWITCHES IN
THE TRANSMITTER

MULTI-CHANNEL TRANSMITTERS:

SET THE RECEIVER BANK NUMBER (1-4) ON THE
OPTION SWITCHES IN THE TRANSMITTER

16 RECEIVER

CHANNELS

4 TRANSMITTER

CHANNELS

4 RECEIVER

BANKS

REFER TO THE SPECIFIC TRANSMITTER INSTRUCTIONS
FOR ACTUAL SWITCH "ON"/"OFF" SETTINGS FOR
EACH MODEL OF TRANSMITTER

MEASURE

VOLTAGE

DCV

+ 12 VDC

POWER

INPUT

RCVR

OUTPUT

CHANNEL

NORMALLY OPEN
OUTPUTS WILL SWITCH
TO GROUND WHEN ACTIVE

1. APPLY POWER TO THE
RECEIVER AND TRANSMITTER(S).
THE RECEIVER'S POWER
INDICATOR SHOULD LIGHT AND
DASHES SHOULD MOVE ACROSS
THE DISPLAY.

2. ACTIVATE AND MAINTAIN A
TRANSMITTER INPUT (WITH
AUTO-RESTORE OFF). DISPLAY
SHOULD SHOW THE CHANNEL #
AND AN "A".

4. RESTORE THE TRANSMITTER'S
INPUT. THE CHANNEL # AND THE "A"
SHOULD GO AWAY.

3. VERIFY THAT THE CHANNEL'S
OUTPUT ACTIVATES WHILE THE "A" IS
ON THE DISPLAY. USE A METER OR
CHECK THE CONNECTED DEVICE.

CH5

CH1

CH2

CH3

CH4

GND

CH6

CH7

CH8

XR-16 RECEIVER

MOOSE Z1100 ALARM PANEL

ZN1

1

COM

2

ZN2

3

ZN3

4

COM

5

ZN4

6

ZN5

7

COM

8

ZN6

9

AUX

POWER

2.2K EOL

RESISTORS

(ZONES PROGRAMMED NORMALLY OPEN)

ZN7

10

COM

11

ZN8

12

28

29

C&K 236 ALARM PANEL

Z1

C

Z2

Z3

C

Z4

Z5

C

Z6

AUX

POWER

AUX

C

+12
VDC

GND

CH5

CH1

CH2

CH3

CH4

GND

CH6

XR-16 RECEIVER

2.2K EOL

RESISTORS

(ZONES PROGRAMMED NORMALLY OPEN)

+12
VDC

GND

THE XR-16 RECEIVER CAN BE CONNECTED TO COMMON
ALARM CONTROL PANELS OR MANY OTHER EXTERNAL DEVICES

Advertising