10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

z

ero

C

learanCe

f

ireplaCe

i

nstallation

This insert may be installed in a masonry or factory built/zero

clearance (ZC) fireplace. When installing in a ZC fireplace,

the ZC grate must be removed and the ZC damper must be

removed or secured open. The ZC doors, screen, refrac-

tory or masonry lining, baffles, and smoke shelf may be

removed if necessary to install the gas insert. However, do

not cut or alter the fireplace components. The removal of

any parts to facilitate installation must not alter the integrity

of the inner or outer shells of the fireplace cabinet. Any parts

removed must be replaceable if the insert is taken out of the

fireplace or the fireplace must be clearly marked with the

metal label that states: "This fireplace has been altered and

is no longer safe to operate." The insert is designed to fit

into a ZC fireplace with a minimum firebox height of 17-1/4"

(438mm). To facilitate this the hood will need to be removed

and discarded (Note: The screws should be replaced in the

insert body). Installation of the flue collar is removable (see

Flue Collar Connection).

If the factory-built fireplace has no gas access hole(s) pro-

vided, an access hole of 1-1/2" (37.5 mm) or less may be

drilled through the lower sides or bottom of the firebox in

a proper workmanship like manner. This access hole must

be plugged with a non-combustible insulation after the gas

supply line has been installed.

The installer must mechanically attach the marking supplied

with the gas fireplace insert to the inside of the firebox of the

fireplace into which the gas fireplace insert is installed.

l

og

s

et

i

nstallation

*Brick Panels are not offered for the Medina™ Gas Insert.

1. Remove log rack (2 screws) and install rear log on retainer.

See Figures 7 & 8).

2. Reinstall log rack with rear log. IMPORTANT!!! SCREWS

PASS THROUGH LOG RACK AND BURNER PAN.

3. Install light layer of mineral wool directly over ports. See

Figure 9.

- A light layer will give a more constant rear flame.

- A heavy layer will give more glow, but will need to be

adjusted after light up.

4. Install front logs on retainer slots. See Figure 10.

5. Place top log on pin. See Figure 11.

6. Place black embers around perimeter of mineral wool.

Important!!! Do not cover ports with black embers. See

Figure 11.

Figure 7

Figure 8

Figure 9

Retainer

Rear log

2 Screws