Clearances to combustibles – Lennox International Inc. Direct-Vent Gas User Manual

Page 8

Advertising
background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Facing &

Mantel -

Side View

f

aCing

and

m

antel

C

learanCes

Note: Hearth protection to be min. /8” (10mm) thick non-
combustible or equivalent, with a k factor of .84.

i

nsert

l

eveling

At each front and rear corner of the insert is an adjustable leg

provided to level the insert should the hearth of the fireplace

be uneven. To adjust the legs, loosen the two 5/32" allen head

screws, move the leg to the desired height, and then tighten

the screws. Repeat these steps for each adjusting leg.

G

13”(330mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

E

H

F

G

J

CL

MANTEL

TRIM

Mantel

Trim

Hearth / Floor Protection

E = 31-1/2" (800mm) from Top Facing to Bottom of

Insert

F = 25-1/2” (648mm) from Center of Glass to Side Facing

or Side Wall

J = 39” (991mm) from 10.5” (267mm) Mantel to Bottom

of Insert

h

earth

p

roteCtion

G = Minimum Hearth Protection from Front of Insert*

H = Vertical Distance from Insert Bottom to Combustible

Material.

Clearances to Combustibles

m

inimum

C

learanCes

to

C

ombustibles

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

31-1/2”

800mm

33-1/2”

851mm

36-1/2”

927mm

39-1/2”

1003mm

C

learanCes

Figure 4

Figure 5