Fuse replacement

This appliance is fitted with a non-rewireable 13 amp mains plug. The plug

contains a 5 amp fuse. If the fuse has blown it can be replaced as follows:

a)

Pull out the red fuse cover/carrier.

b) Remove and dispose of the blown fuse.

c)

Fit a new 5 amp BS1362 approved fuse into the carrier and push the

carrier back into the plug.

Always ensure the fuse cover is fitted. If the fuse cover is missing do not

use the plug. Contact your Linn retailer to obtain a replacement fuse cover.

Fuses are for fire protection and do not protect against electric shock.

Mains plug replacement

Should your mains plug need replacing and you are competent to do

this proceed as follows. If you are in doubt contact your Linn retailer or a

competent electrician.

a)

Disconnect the plug from the mains supply.

b) Cut off the plug and dispose of it safely. A plug with bared

conductors is dangerous if engaged in a live socket.

c)

Only fit a 13 amp BS1363A approved plug with a 5 amp fuse.

d) The cable wire colours or a letter will be marked at the connection

points of most quality plugs.

Attach the wires securely to their respective points. The Brown wire must

go to the Live pin, the Blue wire must go to the Neutral pin, and the Green/

Yellow wire must go to the Earth pin.

e)

Before replacing the plug top ensure that the cable restraint is

holding the outer sheath of the cable firmly and that the wires are

correctly connected.

WARNING

THIS APPLIANCE MUST BE EARTHED.

Linn Products Ltd declare that this product is in conformance with the Low

Voltage Directive 73/23/EEC and Electromagnetic Compatibility 89/336/

EEC as amended by 92/31/EEC and 93/68/EEC.

The conformity of the designated product with the provisions of Directive

number 73/23/EEC (LVD) is proved by full compliance with the following

standards:

Standard number Date of issue

Test type

EN60065

2002

General requirements

Marking

Hazardous

radiation

Heating under normal conditions

Shock hazards under normal

operating

conditions

Insulation

requirements

Fault

conditions

Mechanical

strength

Parts connected to the mains

supply

Components

Terminal

devices

External flexible cords

Electrical connections and

mechanical

fixings

Protection against electric shock

Stability and mechanical hazards

Resistance to fire

The conformity of the designated product with the provisions of Directive

number 89/336/EEC (EMC) is proved by full compliance with the following

standards:

Standard number Date of issue

Test type

EN55013

2001

Conducted emissions

EN55013

2001

Absorbed emissions

EN55020

2002

Immunity

UK Users Please Read This
Important Safety Information

CE Declaration of Conformity

iii

KLIMAX DS

Advertising