INSTALLATION

INVERTEC V200-T

A-5

SHIELDING GAS CONNECTION

An adjustable gas pressure regulator and flow gage
should be obtained. Obtain the necessary inert shield-
ing gas (usually argon). Connect the cylinder of gas
with the pressure regulator and flow gage. Install the
gas hose between the regulator and gas inlet (located
on the low left rear of the welder). The gas inlet has a
5/16-18 right hand female thread; CGA #032.

REMOTE CONTROL CONNECTION

A remote control receptacle is provided on the lower
center case front of the welder for connecting a
remote control to the machine. Refer to the Optional
Accessories section of this manual for available
remote controls.

CYLINDER could explode
if damaged.

•Keep cylinder upright and chained

to a support.

•Keep cylinder away from areas where it could

be damaged.

•Never allow the torch to touch the cylinder.

•Keep cylinder away from live electrical circuits.

•Maximum inlet pressure 150 psi.

___________________________________________

WARNING

QUICK DISCONNECT PLUG (FOR WORK CABLE)

A quick disconnect system is used for the welding
cable connections. The electrode and work cables
need to have a plug attached.

1. Cut off welding cable lug, if present.
2. Remove .75 in. (19mm) of welding cable insulation.
3. Slide rubber boot onto cable end. The boot end

may be trimmed to match the cable diameter. Use
soap or other nonpetroleum-based lubricant to
help slide the boot over the cable, if needed.

4. Cut 45-50% of the copper strands back 1/4” (6

mm).

5. Fold copper strands over cut strands and insert

into ferrule.

6. Slide the copper ferrule into the brass plug.

7. Tighten set screw to collapse copper tube. Screw

must apply pressure against welding cable. The
top of the set screw will be well below the surface
of the brass plug after tightening.

8. Slide rubber boot over brass plug. The rubber boot

must be positioned to completely cover all electri-
cal surfaces after the plug is locked into the recep-
tacle.

19 mm

.75 in.

WELDING CABLE

BOOT

TRIM, IF REQ'D
TO FIT OVER CABLE

6 mm

.25 in.

WELDING CABLE

12 mm max.

.50 in. max

WELDING CABLE

COPPER FERRULE

SET SCREW

BRASS PLUG

COPPER TUBE