Installation, Technical specifications - v200t tig, Physical dimensions – Lincoln Electric INVERTEC V200-T User Manual

Page 8: Operating temperature storage temperature

Advertising
background image

A-1

INSTALLATION

INVERTEC V200-T

A-1

TECHNICAL SPECIFICATIONS - V200T TIG

For DC TIG Welding at 200A/20% Duty Cycle

Based on the 1996 U.S. National Electrical Code

Code

Number

10463

Volts at Rated Amperes

28
26
25

Type of Output

DC

Input Current at

Rated Output

45/23 A @ 200 A, 33/16 A @ 150 A,

25/13 A @ 120 A

Amps

200
150
120

Maximum Open

Circuit Voltage

80 V

Standard

Voltage

(1)

230/460/1/50/60

Duty Cycle

(2)

20% Duty Cycle
60% Duty Cycle
100% Duty Cycle

Output Current

Range

1 - 200 A

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

Input

Voltage /

phase/

Frequency

230/1/50/60

460/1/50/60

Input

Ampere

Rating on

Nameplate

45

23

Type 75°C

Copper Ground

Wire in Conduit

AWG (IEC)

Sizes

10 (5.2 mm2)

12 (4 mm2)

Fuse

(Super Lag)

or Breaker

Size

50

30

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

10 (5.2 mm2)

12 (4 mm2)

Height

Width

Depth

Weight

Power

10.04 in.

7.48 in.

17.32 in.

Approx. 35 lbs.

Source

255 mm

190 mm

440 mm

16 kgs.

PHYSICAL DIMENSIONS

-20°C to +40°C

-25°C to +55°C

OPERATING TEMPERATURE

STORAGE TEMPERATURE

(1) Input voltage must be within ±10% of rated value.

(2) Duty Cycle is

based on a 10 min. period.