Operation, Safety precautions, Warning – Lincoln Electric IDEALARC DC-400 User Manual

Page 14: Warning meanings of graphic symbols

Advertising
background image

b-1

OPERATION

IDEALARC® DC-400

b-1

SAFETY PRECAUTIONS

When using a DC-400 power source with wire feeders
which do not have an electrical trigger interlock (or
with wire feeders with the electrical trigger interlock in
the OFF position), there will be a small spark if the
electrode contacts the work or ground within several
seconds after releasing the trigger.

When used with some wire feeders with the electrical
trigger interlock in the ON position, the arc can restart
if the electrode touches the work or ground during
these several seconds.

• Be sure to select OUTPUT TERMINALS “REMOTE

ON/OFF” for operation with wire feeders that have
leads numbered 2 and 4.

ELECTRIC SHOCK

can kill.

• Have an electrician install and ser-
vice this equipment.
• Turn the input power off at the fuse
box before working on equipment.

• Do not touch electrically hot parts.
• This next section applies to DC-400’s without

the Capacitor Discharge Option:

WARNING

WARNING

MEANINGS OF GRAPHIC SYMbOLS

The DC-400 nameplate has been redesigned to use
international symbols in describing the function of the
various components. Below are the symbols used.

POWER ON-OFF SWITCH

Input (Power)

On

Off

OUTPUT CONTROL DIAL

Output (Control)

Increase/Decrease of
Output (Voltage or
Current)

OUTPUT CONTROL “LOCAL-REMOTE” SWITCH

Remote Output Voltage
or Current Control

Local Output Voltage or
Current Control

CIRCUIT bREAKER

THERMAL PROTECTION LIGHT

ARC CONTROL SWITCH

Circuit breaker

High Temperature

Gas

Metal

Arc

Welding

Increase/Decrease
of Inductance

Low Inductance

High Inductance

Advertising